SPACE QUALIFIED POINT OF LOAD CONVERTERS

SVFA0510SK 数据手册

 浏览型号SVFA0510SK的Datasheet PDF文件第4页浏览型号SVFA0510SK的Datasheet PDF文件第5页浏览型号SVFA0510SK的Datasheet PDF文件第6页浏览型号SVFA0510SK的Datasheet PDF文件第8页浏览型号SVFA0510SK的Datasheet PDF文件第9页浏览型号SVFA0510SK的Datasheet PDF文件第10页 
SVFA0510S Series  
6.3 PROTECTION FEATURES  
6.3.1 Input Undervoltage Lockout  
The SVFA0510S Series provides input undervoltage lockout protection. For input voltages below the turn-on voltage, the converter will  
remain off. When the input voltage exceeds the turn-on voltage, the converter will start. For input voltages below the operating range of  
the converter but above the UVLO turn-off voltage, the converter may reach its maximum duty cycle and the output may drop out of  
regulation.  
6.3.2 Output Soft-Start  
The SVFA0510S Series utilizes an output soft-start function to ramp the output in a controlled manner, eliminating output voltage  
overshoot and limiting inrush current at turn on. A voltage mode soft-start ensures the output waveform remains consistent regardless  
of changes in the load current. The output rise time is approximately 3 ms. The soft-start function is active whether the module is  
turned on with an application of input voltage or from release of the INH pin. The turn-on delay time is specified from the application of  
input voltage (or release of INH pin) until the output reaches 90% of its final value.  
6.3.3 Output Short Circuit Protection  
The SVFA0510S Series provides output short circuit protection. When a sustained high peak current is detected, the converter will shut  
down and enter a hiccup mode. After a delay, the converter will attempt a soft-start. This sequence will continue until the fault is  
removed, allowing the converter to soft-start and resume normal operation.  
6.4 THERMAL CONSIDERATIONS  
The SVFA0510S is rated for full power operation at 125 °C. Operation above 125 °C is allowed at reduced power. Specifically, the  
output power should be derated linearly from full power at 125 °C to half power at 130 °C and to zero power at 135 °C. The operating  
temperature of the converter is specified on the baseplate of the converter. The converter is designed to be conduction-cooled, with the  
baseplate mounted to a heat sink, chassis, PCB or other thermal surface. The internal power dissipating components are mounted to  
the baseplate of the converter and all heat flow is through the baseplate. The lid of the converter does not provide a good thermal path.  
The hybrid DC-DC converter contains many semiconductor components. The maximum temperature rise from junction to case is 11 °C  
at full load.  
Sales Information  
Phone:(425) 353-3010  
Fax: (425) 353-4030  
SVFA0510S - 6.0  
Page 7  
E-mail: vptsales@vptpower.com  
Web: www.vptpower.com  

与SVFA0510SK相关器件

型号 品牌 描述 获取价格 数据表
SVFA0515S VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格

SVFA0515SEM VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格

SVFA0515SG VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格

SVFA0515SGNEME VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格

SVFA0515SGNHE VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格

SVFA0515SGNKE VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格