SVFA0510SG Series  
6.0 TECHNICAL NOTES  
Please note that many of these functions are also demonstrated in detail on the VPT website in the  
form of technical video labs.  
6.1 GENERAL INFORMATION  
6.1.1 Topology Description  
The SVFA0510SG is a non-isolated, fixed-frequency, radiation-hardened, synchronous buck  
converter. It operates from a 5 V input and provides a stepped-down, precisely regulated, programmable output voltage at high  
efficiency. The SVFA0510SG is optimized for low voltage point-of-load (POL) applications.  
6.1.2 External Components  
The SVFA0510SG Series has internal input and output capacitors. To meet the performance specifications in Section 3.2, a minimum  
additional 100 µF tantalum input decoupling capacitor is required. The SVFA0510SG is stable with no load capacitance. Additional  
output capacitance is allowed up to the maximum listed in Section 3.2.  
6.1.3 Source Impedance  
The impedance of the 5V input source can interact with the POL converter and can affect performance. High source impedance is often  
caused by a long input cable or other components added in series with the input. In some cases, additional input capacitance will be  
needed to stabilize the system.  
6.1.4 Case Connection  
The SVFA0510SG case is connected to GND at a single point inside of the package.  
6.2 FUNCTION DESCRIPTIONS  
VIN  
6.2.1 On/Off Control (Inhibit)  
The INH (Inhibit) pin is a control pin referenced to GND. The INH pin must be driven  
using an open-collector or open-drain configuration. Pulling the INH pin low disables  
INH  
the converter output. Leaving INH open enables the output, allowing the converter to  
operate normally. The pin must be pulled below 1.5V to disable the output. An  
OPTIONAL  
CAPACITOR  
optional capacitor from INH to GND may be used to delay turn-on. The INH pin should  
be left open if not used.  
GND  
Sales Information  
Phone:(425) 353-3010  
Fax: (425) 353-4030  
SVFA0510SG - 3.0  
Page 7  
E-mail: vptsales@vptpower.com  
Web: www.vptpower.com  

与SVFA0510SGNEME相关器件

型号 品牌 描述 获取价格 数据表
SVFA0510SGNHE VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格

SVFA0510SGNKE VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格

SVFA0510SH VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格

SVFA0510SK VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格

SVFA0515S VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格

SVFA0515SEM VPT SPACE QUALIFIED POINT OF LOAD CONVERTERS

获取价格