Table 7. Pressure Range Specifications for ±2.5 mbar to ±40 mbar
Order
Code
(See
Long-term
Stability
(1000 hr,
Pressure Range
Total Error
Band after
Auto-Zero17
Common
Mode
Total Error
Band16
Working
Over-
Burst
Pressure10 pressure18 Pressure19
Pressure20
Pmin.
Pmax.
Fig. 1)
25 °C [77 °F])
Differential
0.5 %FSS
0.5 %FSS
0.5 %FSS
0.5 %FSS
0.5 %FSS
0.35 %FSS
0.35 %FSS
Gage
2.5MD
004MD
006MD
010MD
016MD
025MD
040MD
5 %FSS
3.5 %FSS
2.5 %FSS
2 %FSS
2 %FSS
2 %FSS
2 %FSS
1.5 %FSS
1.5 %FSS
1 %FSS
-2.5 mbar 2.5 mbar
335 mbar
335 mbar
335 mbar
375 mbar
375 mbar
435 mbar
435 mbar
675 mbar 1000 mbar 3450 mbar
675 mbar 1000 mbar 3450 mbar
675 mbar 1000 mbar 3450 mbar
750 mbar 1250 mbar 5450 mbar
750 mbar 1250 mbar 5450 mbar
850 mbar 1350 mbar 10450 mbar
850 mbar 1350 mbar 10450 mbar
-4 mbar
-6 mbar
4 mbar
6 mbar
-10 mbar 10 mbar
-16 mbar 16 mbar
-25 mbar 25 mbar
-40 mbar 40 mbar
0.75 %FSS
0.75 %FSS
0.75 %FSS
0.75 %FSS
004MG
006MG
010MG
016MG
025MG
040MG
5 %FSS
5 %FSS
2.5 %FSS
2.5 %FSS
2 %FSS
2 %FSS
1.5 %FSS
1.25 %FSS
1 %FSS
0.5 %FSS
0.5 %FSS
0.5 %FSS
0.5 %FSS
0.5 %FSS
0.5 %FSS
0 mbar
0 mbar
0 mbar
0 mbar
0 mbar
0 mbar
4 mbar
6 mbar
335 mbar
335 mbar
335 mbar
335 mbar
375 mbar
375 mbar
675 mbar 1000 mbar 3450 mbar
675 mbar 1000 mbar 3450 mbar
675 mbar 1000 mbar 3450 mbar
675 mbar 1000 mbar 3450 mbar
750 mbar 1250 mbar 5450 mbar
750 mbar 1250 mbar 5450 mbar
10 mbar
16 mbar
25 mbar
40 mbar
1 %FSS
0.75 %FSS
0.75 %FSS
Notes:
16. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range.
Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal
effect on span, and thermal hysteresis. (See Figures 3 and 4.)
17. Total Error Band After Auto-Zero: The maximum deviation from the ideal transfer function over the entire compensated pressure range at a
constant temperature and supply voltage for a minimum of 24 hours after an auto-zero operation. Includes all errors due to full scale span,
pressure non-linearity, pressure hysteresis, and thermal effect on span.
18. Overpressure: The absolute maximum rating for pressure which may safely be applied to the product for it to remain in specification once
pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless
otherwise specified this applies to all available pressure ports at any temperature with the operating temperature range. Tested to 10,000
cycles, minimum. (See Figure 5.)
19. Burst Pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product
should not be expected to function after exposure to any pressure beyond the burst pressure. (See Figure 5.)
20. Common Mode Pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without
causing changes in specified performance.
Table 8. Pinout for SMT and DIP Packages
Output Type
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
analog
NC
Vsupply
OUTPUT+
GND
NC
NC
NC
NC
Table 9. Pinout for SIP Package
Output Type
Pin 1
Pin 2
Pin 3
OUTPUT+
Pin 4
analog
NC
Vsupply
GND
Honeywell Sensing and Control
7