Figure 1. Nomenclature and Order Guide
_
A
A
_
_ _ _ _ _ _ _ _
SSC
Supply Voltage
3 = 3.3 Vdc
Series
5 = 5.0 Vdc
Package
D = DIP (Dual Inline Pin)
M = SMT (Surface Mount Technology)
S = SIP (Single Inline Pin)
Transfer Function12
A = 10% to 90% of Vsupply
Output Type13
A = Analog voltage
Pressure Port
DIP
Pressure Range14, 15
SMT
SIP
inH2O (at 4 °C)
mbar
Differential
NN = No ports
NN = No ports
NN = No ports
Differential
001ND = ±1 inH2O
002ND = ±2 inH2O
004ND = ±4 inH2O
005ND = ±5 inH2O
010ND = ±10 inH2O
020ND = ±20 inH2O
030ND = ±30 inH2O
2.5MD = ±2.5 mbar
004MD = ±4 mbar
006MD = ±6 mbar
010MD = ±10 mbar
016MD = ±16 mbar
025MD = ±25 mbar
040MD = ±40 mbar
AA = Dual
axial barbed
ports, opposite
sides
-
-
AN = Single
axial barbed
port
AN = Single
axial barbed
port
AN = Single
axial barbed
port
Gage
Gage
002NG = 0 inH2O to 2 inH2O 004MG = 0 mbar to 4 mbar
004NG = 0 inH2O to 4 inH2O 006MG = 0 mbar to 6 mbar
005NG = 0 inH2O to 5 inH2O 010MG = 0 mbar to 10 mbar
010NG = 0 inH2O to 10 inH2O 016MG = 0 mbar to 16 mbar
020NG = 0 inH2O to 20 inH2O 025MG = 0 mbar to 25 mbar
030NG = 0 inH2O to 30 inH2O 040MG = 0 mbar to 40 mbar
LN = Single
axial barbless
port
LN = Single
axial barbless
port
LN = Single
axial barbless
port
FF = Fastener
mount, dual axial
barbed ports,
-
-
Options
opposite sides
N = Gases only, no special options
D = Gases only, diagnostics on
T = Liquid media on Port 1, no diagnostics*
V = Liquid media on Port 1, diagnostics on*
FN = Fastener
mount, single axial
barbed port
-
-
-
-
-
GN = Ribbed
fastener mount,
single axial
CAUTION
PRODUCT DAMAGE
barbed port
NB = Fastener
mount, dual axial
ports, same side
· Ensure liquid media is applied to Port 1 only; Port 2 is
not compatible with liquids.
-
· Ensure liquid media contains no particulates. All
TruStability® sensors are dead-ended devices.
Particulates can accumulate inside the sensor, causing
damage or affecting sensor output.
RN = Single
radial barbed
port
RN = Single
radial barbed
port
RN = Single
radial barbed
port
RR = Dual
radial barbed
ports, same
side
RR = Dual
radial barbed
ports, same
side
RR = Dual
radial barbed
ports, same
side
· Recommend that the sensor be positioned with Port 1
facing downwards; any particulates in the system are
less likely to enter and settle within the pressure sensor
if it is in this position.
DR = Dual
radial barbed
ports, opposite
sides
DR = Dual radial
barbed ports,
opposite sides
DR =Dual radial
barbed ports,
opposite sides
· Ensure liquid media does not create a residue when
dried; build-up inside the sensor may affect sensor
output. Rinsing of a dead-ended sensor is difficult and
has limited effectiveness for removing residue.
HH = Fastener
mount, dual
radial barbed
ports, same
side
· Ensure liquid media are compatible with wetted
materials. Non-compatible liquid media will degrade
sensor performance and may lead to sensor failure.
Failure to comply with these instructions may result in
product damage.
-
-
-
-
HN = Fastener
mount, single
radial barbed port
MN = Manifold
mount, outer
diameter seal
-
-
-
-
*Indicates available soon.
SN = Manifold
mount, inner
diameter seal
Notes:
12. The transfer function limits define the output of the sensor at a given pressure input. By specifying Pmin. and Pmax., the output at Pmin. and
transfer functions are available. Contact Honeywell Sales and Service for more information.
13. Digital output is also available. Contact Honeywell Sales and Service for more information.
14. Custom pressure ranges are available. Contact Honeywell Sales and Service for more information.
15. See Table 5 for an explanation of sensor pressure types.
Honeywell Sensing and Control
5