Table 3. Environmental Specifications  
Parameter  
Characteristic  
Humidity:  
Dry gases only (See “Options N and D” in Figure 1.)  
Liquid media (See “Options T and V” in Figure 1.)  
0% to 95% RH, non-condensing  
100% condensing or direct liquid media on Port 1  
MIL-STD-202F, Curve AK (20.7 g random)  
MIL-STD-202F, Method 213B, Condition F  
1 million cycles minimum  
Vibration  
Shock  
Life9  
Solder reflow  
J-STD-020-C  
Table 4. Wetted Materials10  
Parameter  
Covers  
Substrate  
Port 1 (Pressure Port)  
high temperature polyamide  
alumina ceramic  
Port 2 (Reference Port)  
high temperature polyamide  
alumina ceramic  
Adhesives  
epoxy, silicone  
epoxy, silicone  
Electronic components  
Notes:  
ceramic, glass, solder, silicon  
silicon, glass, gold, solder  
1. Absolute maximum ratings are the extreme limits the device will withstand without damage.  
2. Ratiometricity of the sensor (the ability of the device to scale to the supply voltage) is achieved within the specified operating voltage for each  
option.  
3. The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.  
4. The compensated temperature range is the temperature range over which the sensor will produce an output proportional to pressure within  
the specified performance limits.  
5. The operating temperature range is the temperature range over which the sensor will produce an output proportional to pressure but may not  
remain within the specified performance limits.  
6. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at  
25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.  
7. Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range.  
Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal  
effect on span, and thermal hysteresis.  
8. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of  
the pressure range. (See Figure 1 for ranges.)  
9. Life may vary depending on specific application in which sensor is utilized.  
10. Contact Honeywell Customer Service for detailed material information.  
CAUTION  
PRODUCT DAMAGE  
Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids.  
Ensure liquid media contains no particulates. All TruStability® sensors are dead-ended devices. Particulates can accumulate  
inside the sensor, causing damage or affecting sensor output.  
Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to  
enter and settle within the pressure sensor if it is in this position.  
Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a  
dead-ended sensor is difficult and has limited effectiveness for removing residue.  
Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance and  
may lead to sensor failure.  
Failure to comply with these instructions may result in product damage.  
Honeywell Sensing and Control  
3

与SSCDNND001BGAA3相关器件

型号 品牌 描述 获取价格 数据表
SSCDNND001BGAB3 HONEYWELL Peizoresistive Sensor, Gage, 0Psi Min, 14.5Psi Max, 0.25%, Rectangular, Through Hole Mount

获取价格

SSCDNND001PD2A3 HONEYWELL TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,

获取价格

SSCDNND001PD2A5 HONEYWELL TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,

获取价格

SSCDNND001PD3A3 HONEYWELL TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,

获取价格

SSCDNND001PD3A5 HONEYWELL TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,

获取价格

SSCDNND001PD4A3 HONEYWELL TruStability silicon Pressure Sensors: SSC Series-Standard Accuracy +-2% total Error band,

获取价格