SPU15A SERIES
15W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU15A series of AC/DC switching mode power
supplies provide 15 Watts of continuous output power. All
supplies are UL 94V-0 compliant, include IEC-320-C14
input for worldwide applications. All models meet FCC class
B and CISPR class B emission Limits and are designed to
comply with UL, C-UL, TUV and CE requirements. All units
are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 264VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Output Voltage Available From 3VDC Thru 48VDC
Optional Output Connector (See appendix)
Single Output
Splash proof
Class I Insulation
Two years warranty
Safety Approvals:
P
S
E
CB
Electrical Characteristics:
Sym.
Vin Input Voltage
Fin Input Frequency
Parameter
Test Conditions
Min. Typ. Max. Unit
90
47
264
63
VAC
Hz
W
Wo
Vo
Io
Output Power Range
Output Voltage Range
Output Current Range
Vin=90 to 264VAC
15
See rating chart V
See rating chart A
Iil Input Current (Low Line)
Iih Input Current (High Line)
Io=Full load, Vin=115VAC
Io=Full load, Vin=230 VAC
0.4
A
A
0.26
Io=Full load, 25°c, Cool start,
Irl Low Line Inrush Current
12
15
A
Vin=115VAC
Io=Full load, 25°c, Cool start,
Irh High Line Inrush Current
26
30
85
1
A
Vin=230VAC
Eff Efficiency
Io=Full Load, Vin=230VAC
Io=Full Load
60
75
0.5
3
%
%
REG-i Line Regulation
REG-o Load Regulation
OVP Over Voltage Protection
OCP Over Current Protection
Ttr Transient Response
Thold Hold-Up Time
Vin=230VAC
7
%
Nil
%
Nil.But,Output protected to short circut conditions
%
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=100VAC
4
mS
mS
S
5
Ts
Start Up Time
Io=Full Load, Vin=100VAC
0.3
1
2
2
Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
Tc Temperature Coefficient All output
1
%
0.5 0.75
0.04
mA
%/°c
-0.04
Environmental :
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Toper Operating Temperature
Tstg Storage Temperature
0
-40
5
70
85
95
°c
°c
%
Hr
Pd
Relative Humidity
Derate linearly from 100% load at 40°c to 50% load at 70°c