SMD POWER INDUCTORS  
SPC3012FT SERIES  
6. RELIABILITY & TEST CONDITION :  
ITEM  
PERFORMANCE  
TEST CONDITION  
Electrical Characteristics Test  
Dielectric withstand voltage  
There shall be no damage or problems.  
AC 100V voltage shall be applied for 1 minute across the  
top surface and the terminal of this sample  
Temperature characteristics  
High temperature storage  
ǻL/L20°C<±10%  
The test shall be performed after the sample has stabilized  
in an ambient temperature of -20 to +85°C,and the value  
calculated based on the value applicable in a normal  
0~2000 ppm/°C  
temperature and normal humidity shall be ǻL/L20°C<±10%.  
ǻL/Lo<±10%  
The sample shall be left for 96±4 hours in an atmosphere  
with a temperature of 85±2°C and a normal humidity.  
Upon completion of the measurement shall be made after  
the sample has been left in a normal temperature and  
normal humidity for 1 hour.  
There shall be no mechanical damage.  
Low temperature storage  
Change of temperature  
ǻL/Lo<±10%  
There shall be no mechanical damage.  
The sample shall be left for 96±4 hours in an atmosphere  
with a temperature of -25±3°C.  
Upon completion of the test, the measurement shall be  
made after the sample has been left in a normal temperature  
and normal humidity for 1 hour.  
ǻL/Lo<±10%  
The sample shall be subject to 5 continuous cycles, such as  
shown in the table 2 below and then it shall be subjected to  
standard atmospheric conditions for 1 hour, after which  
measurement shall be made.  
There shall be no other damage of problems  
Temperature  
-25±3°C  
(Thermostat No.1)  
Standard  
atmospheric  
Duration  
30 min.  
1
2
5 sec. or less  
No.1ĺNo.2  
85±2°C  
30 min.  
3
4
(Thermostat No.2)  
5 sec. or less  
No.2ĺNo.1  
Standard  
atmospheric  
Moisture storage  
ǻL/Lo<±10%  
The sample shall be left for 96±4 hours in a temperature of  
40±2°C and a humidity(RH) of 90~95%.  
Upon completion of the test, the measurement shall be  
made after the sample has been left in a normal temperature  
and normal humidity more than 1 hour.  
There shall be no mechanical damage.  
NOTE : Specifications subject to change without notice. Please check our website for latest information.  
04.01.2010  
SUPERWORLD ELECTRONICS (S) PTE LTD  
PG. 4  

与SPC3012FT-100MZF相关器件

型号 品牌 获取价格 描述 数据表
SPC3012FT150F SUPERWORLD

获取价格

Low Profile Power Inductors
SPC3012FT-150MZF SUPERWORLD

获取价格

SMD POWER INDUCTORS
SPC3012FT1R0F SUPERWORLD

获取价格

Low Profile Power Inductors
SPC3012FT-1R0NZF SUPERWORLD

获取价格

SMD POWER INDUCTORS
SPC3012FT1R2F SUPERWORLD

获取价格

Low Profile Power Inductors
SPC3012FT-1R2NZF SUPERWORLD

获取价格

SMD POWER INDUCTORS
SPC3012FT1R5F SUPERWORLD

获取价格

Low Profile Power Inductors
SPC3012FT-1R5NZF SUPERWORLD

获取价格

SMD POWER INDUCTORS
SPC3012FT220F SUPERWORLD

获取价格

Low Profile Power Inductors
SPC3012FT-220MZF SUPERWORLD

获取价格

SMD POWER INDUCTORS