SN54/74LS247 • SN54/74LS248 • SN54/74LS249
LS247
FUNCTION TABLE
DECIMAL
OR
FUNCTION
INPUTS
OUTPUTS
d
BI/RBO
NOTE
LT
RBI
D
C
B
A
a
b
c
e
f
g
0
1
2
3
H
H
H
H
H
X
X
X
L
L
L
L
L
L
L
L
L
L
H
H
L
H
L
H
H
H
H
ON
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
OFF
OFF OFF OFF
ON
OFF OFF
OFF
ON
ON
H
ON
ON
4
5
6
7
H
H
H
H
X
X
X
X
L
L
L
L
H
H
H
H
L
L
H
H
L
H
L
H
H
H
H
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
H
OFF
OFF OFF OFF
1
8
9
10
11
H
H
H
H
X
X
X
X
H
H
H
H
L
L
L
L
L
L
H
H
L
H
L
H
H
H
H
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
OFF OFF OFF
OFF OFF ON
H
OFF OFF
12
13
14
15
H
H
H
H
X
X
X
X
H
H
H
H
H
H
H
H
L
L
H
H
L
H
L
H
H
H
H
OFF
ON
ON
OFF OFF
OFF OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF OFF OFF
OFF OFF OFF OFF
H
OFF OFF OFF
BI
RBI
LT
X
H
L
X
L
X
X
L
X
X
L
X
X
L
X
X
L
X
L
L
H
OFF OFF OFF OFF
OFF OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
2
3
4
ON
ON
ON
ON
ON
ON
ON
LS248, LS249
FUNCTION TABLE
DECIMAL
OR
FUNCTION
INPUTS
OUTPUTS
d
BI/RBO
a
NOTE
LT
RBI
D
C
B
A
b
c
e
f
g
0
1
2
3
H
H
H
H
H
X
X
X
L
L
L
L
L
L
L
L
L
L
H
H
L
H
L
H
H
H
H
H
L
H
H
H
H
H
H
H
H
L
H
L
H
H
H
L
H
L
H
L
L
L
L
L
H
H
1
1
H
H
4
5
6
7
H
H
H
H
X
X
X
X
L
L
L
L
H
H
H
H
L
L
H
H
L
H
L
H
H
H
H
L
H
H
H
H
L
L
H
H
H
H
L
H
H
L
L
L
H
L
H
H
H
L
H
H
H
L
H
H
1
8
9
10
11
H
H
H
H
X
X
X
X
H
H
H
H
L
L
L
L
L
L
H
H
L
H
L
H
H
H
H
H
H
L
H
H
L
H
H
L
H
H
H
H
H
L
H
L
H
H
L
H
H
H
H
H
L
L
H
L
12
13
14
15
H
H
H
H
X
X
X
X
H
H
H
H
H
H
H
H
L
L
H
H
L
H
L
H
H
H
H
L
H
L
H
L
L
L
L
L
L
L
L
H
H
L
L
L
H
L
H
H
H
L
H
H
H
L
H
L
BI
RBI
LT
X
H
L
X
L
X
X
L
X
X
L
X
X
L
X
X
L
X
L
L
H
L
L
H
L
L
H
L
L
H
L
L
H
L
L
H
L
L
H
L
L
H
2
3
4
H = HIGH Level, L = LOW Level, X = Irrelevant
NOTES: 1. The blanking input (BI) must be open or held at a high logic level when output functions 0 through 15 are desired. The ripple-blanking input (RBI) must
NOTES: 1. be open or high if blanking of a decimal zero is not desired.
2. When a low logic level is applied directly to the blanking input (BI), all segment outputs are off regardless of the level of any other input.
3. When ripple-blanking input (RBI) and inputs A, B, C, and D are at a low level with the lamp test input high, all segment outputs go off and the
NOTES: 1. ripple-blanking output (RBO) goes to a low level (response condition).
4. When the blanking input/ripple blanking output (BI/RBO) is open or held high and a low is applied to the lamp-test input, all segment outputs are on.
BI/RBO is wire-AND logic serving as blanking input (BI) and/or ripple-blanking output (RBO).
FAST AND LS TTL DATA
5-404