Non resettable fuses
SMD-SPT
www.schurter.com/pg0ꢀ_2
Surface Mount Fuse, 5 x 20 mm, Time-Lag T, H, 250 VAC, Au plating
IEC 60127-2 · 250VAC · 300VDC · Time-Lag T
Description
Applications
-ꢀDirectlyꢀsolderableꢀonꢀprintedꢀcircuitꢀboards
-ꢀIECꢀStandardꢀFuse
-ꢀPrimaryꢀProtectionꢀonꢀSMDꢀPCB
References
GeneralꢀProductꢀInformation
PackagingꢀDetails
-ꢀHꢀ=ꢀHighꢀBreakingꢀCapacity
Standards
-ꢀIECꢀ60127-2/5
-ꢀULꢀ248-14
Weblinks
Approvals,ꢀRoHS,ꢀCHINA-RoHS,ꢀe-Store,ꢀDistributor-Stock-Check,ꢀ
Accessories,ꢀProductꢀChangeꢀNotificationꢀ(PCN)
-ꢀCSAꢀC22.2ꢀno.ꢀ248.14
Approvals
-ꢀVDEꢀLicenseꢀNumber:ꢀ40010881
-ꢀULꢀFileꢀNumber:ꢀE41599
Technical Data
RatedꢀVoltage
RatedꢀCurrent
BreakingꢀCapacity
Characteristic
Mountingꢀ
250ꢀVAC,ꢀ300ꢀVDC
1ꢀ-ꢀ16ꢀA
500ꢀAꢀ-ꢀ1500ꢀA
Time-LagꢀT
PCB,SMT
SolderingꢀMethods
Solderability
Reflow
245ꢀ°Cꢀ/ꢀ3ꢀsecꢀacc.ꢀtoꢀIECꢀ60068-2-58,ꢀ
TestꢀTd
ResistanceꢀtoꢀSolderingꢀHeat 260ꢀ°Cꢀ/ꢀ10ꢀsecꢀacc.ꢀtoꢀIECꢀ60068-2-58,ꢀ
TestꢀTd
ResistanceꢀtoꢀVibration
MoistureꢀResistanceꢀTest
acc.ꢀtoꢀIECꢀ60068-2-6,ꢀtestꢀFc
MIL-STD-202,ꢀMethodꢀ106Eꢀ
(50ꢀcyclesꢀinꢀaꢀtemp./misterꢀchamber)
MIL-STD-202,ꢀMethodꢀ211Aꢀ
(Deflectionꢀofꢀboardꢀ1ꢀmmꢀforꢀ1ꢀminute)
MIL-STD-202,ꢀMethodꢀ107Dꢀ
(200ꢀair-to-airꢀcyclesꢀfromꢀ-55ꢀtoꢀ
+125°C)
AdmissibleꢀAmbientꢀAirꢀTemp. -55ꢀ°Cꢀtoꢀ125ꢀ°C
ClimaticꢀCategory
Material:ꢀHousing
Material:ꢀTerminals
UnitꢀWeight
StorageꢀConditions
ProductꢀMarking
55/125/21ꢀacc.ꢀtoꢀIECꢀ60068-1
Ceramic
TerminalꢀStrength
ThermalꢀShock
Gold-PlatedꢀCopperꢀAlloy
1ꢀg
0ꢀ°Cꢀtoꢀ60ꢀ°C,ꢀmax.ꢀ70%ꢀr.h.
,ꢀCurrent,ꢀVoltage,ꢀCharacteristic,ꢀ
BreakingꢀCapacity
CaseꢀResistance
acc.ꢀtoꢀEIA/IS-722,ꢀTestꢀ4.7ꢀ
>100ꢀMΩꢀ(betweenꢀleedsꢀandꢀbody)
MIL-STD-202,ꢀMethodꢀ215A
ResistanceꢀtoꢀSolvents
Dimensions
ꢀ20ꢀmm
0.2
10
5.5
9.5
5.5
0.5
20
Soldering pads
Fuses
ꢀ