SM30 Series 30 mm Barrel Sensors
Speciꢂcaꢀons
Supply Voltage and Current
Environmental Raꢀng
Emiꢂers: 12 to 240V ac (50/60 Hz) or 10-30V dc at 20 mA, 10% maximum
Exceeds NEMA 6P and IEC IP67
ripple
Connecꢀons
DC Receivers: 10 to 30V dc at 10 mA maximum (exclusive of load); 10%
maximum ripple
AC Receivers: 24 to 240V ac (50/60 Hz)
PVC-jacketed 2 m or 9 m cables or Mini-style quick-disconnect (QD) ꢃꢄng are
available. QD cables are ordered separately.
Operaꢀng Condiꢀons
Supply Protecꢀon Circuitry
Temperature: −40 °C to +70 °C (−40 °F to +158 °F)
90% at +50 °C maximum relaꢀve humidity (non-condensing)
Protected against reverse polarity and transient voltages
Output Conꢂguraꢀon
Required Overcurrent Protecꢀon
™
DC Receivers: Bi-Modal output (PNP sourcing or NPN sinking). Selecꢀon of
light/dark operate and sourcing or sinking conꢃguraꢀon dependent on hookup.
AC Receivers: SPST solid-state switch; light operate (LO) or dark operate (DO)
dependent on model.
WARNING: Electrical connecꢀons must be made
by qualiꢃed personnel in accordance with local
and naꢀonal electrical codes and regulaꢀons.
Output Raꢀng
Overcurrent protecꢀon is required to be provided by end product applicaꢀon
per the supplied table.
DC Receivers: 250 mA conꢀnuous
Output saturaꢀon voltage (PNP & NPN conꢃguraꢀon) < 1 volt at 10 mA and < 2
volts at 250 mA
Overcurrent protecꢀon may be provided with external fusing or via Current
Limiꢀng, Class 2 Power Supply.
Off-state leakage current < 10 microamps
AC Receivers: Maximum steady-state load capability is 500 mA
Supply wiring leads < 24 AWG shall not be spliced.
For addiꢀonal product support, go to www.bannerengineering.com.
Inrush capability: 10 amps for 1 second (non-repeaꢀng)
Off-state leakage: current < 1.7 mA rms
On-state voltage drop: < 3.5 volts rms across a 500 mA load; < 5 volts rms
across a 15 mA load
Supply Wiring (AWG)
Required Overcurrent Protecꢀon (Amps)
20
22
24
26
28
30
5.0
3.0
2.0
1.0
0.8
0.5
Output Protecꢀon Circuitry
Outputs of dc receivers are short circuit protected
Output Response Time
10 milliseconds on/off
Repeatability
“A” frequency models: 1 ms
“B” frequency models: 1.5 ms
“C” frequency models: 2.3 ms
Indicators
Internal red LED, visible through the lens or from side of the sensor.
Cerꢀꢂcaꢀons
Emiꢂers: Red “Power ON” indicator LED
DC Receivers: Lights whenever receiver sees its modulated light source
AC Receivers: Lights whenever receiver’s output is conducꢀng
Construcꢀon
Fully epoxy-encapsulated tubular threaded housing, posiꢀve sealed at both
ends, quad-ring sealed acrylic lens.
Plasꢀc models: 30 mm diameter thermoplasꢀc polyester housing and jam nuts.
Stainless Steel models: 30 mm diameter 303 stainless steel housing and jam
nuts.
Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise.
Cabled Models
QD Models
Jam Nuts
(2 Provided)
Jam Nuts
(2 Provided)
Alignment
Indicator (Receivers)
Alignment
Indicator (Receivers)
M30 x 1.5
Thread
M30 x 1.5
Thread
102 mm
(4.0")
114 mm
(4.5")
P/N 03541 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164
3