Multilayer Ceramic Capacitors
Approval Sheet
5. EXTERNAL DIMENSIONS & CONSTRUCTIONS
Size
Inch (mm)
L (mm)
W (mm)
T (mm)/Symbol
Remark
MB (mm)
L
0.25
+0.05/-0.10
0402 (1005)
E
S
#
1.00±0.20
0.50±0.20
0.50±0.20
0.80±0.07
T
1.60±0.20
1.60±0.30
0.80±0.10
0.80±0.30
0603 (1608)
0805 (2012)
0.40±0.15
0.50±0.20
0.80±0.30
0.60±0.10
0.80±0.10
1.25±0.10
1.25±0.30
0.80±0.10
X
A
B
D
I
W
MB
MB
2.00±0.20
2.00±0.30
1.25±0.10
1.25±0.30
#
#
Fig. 1 The outline of MLCC
B
0.95±0.10
1.15±0.15
1.25±0.10
1.60±0.20
1.60±0.50
0.95±0.10
C
J
#
#
#
#
#
#
3.20+0.4/-0.1
1.60±0.15
0.60±0.20
(0.50±0.25)*
1206 (3216)
1210 (3225)
D
G
P
C
3.20+0.4/-0.1
3.20±0.50
1.60±0.20
1.60±0.50
3.20±0.40
2.50±0.20
2.50±0.50
2.03±0.25
3.20±0.30
1.25±0.10
1.60±0.20
2.00±0.20
2.50±0.50
1.25±0.10
2.00±0.20
1.25±0.10
D
G
K
#
#
#
#
#
#
#
0.75±0.25
0.50±0.25
3.20±0.60
M
D
K
1808 (4520) 4.50+0.6/-0.4
D
1.60±0.20
2.00±0.20
2.50±0.50
G
K
#
#
#
#
#
#
0.75±0.25
(0.50±0.25)*
1812 (4532) 4.50+0.6/-0.4
1825 (4563) 4.50+0.6/-0.4
3.20±0.40
6.30±0.40
5.00±0.40
6.30±0.40
M
0.75±0.35
0.85±0.35
0.85±0.35
2.00±0.20 (K)
2.50±0.30 (M)
2.80±0.30 (U)
2220 (5750)
2225 (5763)
5.70±0.50
5.70±0.50
# Reflow soldering only is recommended.
* For 1206≧1000V, 1812_200V~4000V products.
6. GENERAL ELECTRICAL DATA
Dielectric
NP0
X7R
0402, 0603, 0805, 1206, 1210, 1812, 1825, 2220, 2225
100pF to 47µF 0.027µF to 10µF
X5R
Y5V
Size
Capacitance range*
0.1pF to 0.082µF
0.01µF to 4.7µF
Cap≤5pF:
B (±0.1pF), C (±0.25pF)
5pF<Cap<10pF:
C (±0.25pF), D (±0.5pF)
Cap≥10pF:
Capacitance tolerance**
K (±10%), M (±20%)
Z (-20/+80%)
F (±1%), G (±2%),
J (±5%), K (±10%)
Rated voltage (WVDC)
Operating temperature
Capacitance characteristic
Termination
6.3V to 3000V
-55 to +125°C
±15%
-55 to +125°C
±30ppm
-55 to +85°C
±15%
-25 to +85 °C
+30/-80%
Ni/Sn (lead-free termination)
* Measured at the condition of 30~70% related humidity.
NP0: Apply 1.0±0.2Vrms, 1.0MHz±10% for Cap≤1000pF and 1.0±0.2Vrms, 1.0kHz±10% for Cap>1000pF, 25°C at ambient temperature
X7R, X5R: Apply 1.0±0.2Vrms, 1.0kHz±10%, at 25°C am bient temperature.
Y5V: Apply 1.0±0.2Vrms, 1.0kHz±10%, at 20°C ambient temperature.
** Preconditioning for Class II MLCC: Perform a heat treatment at 150±10°C for 1 hour, then leave in a mbient condition for 24±2 hours
before measurement.
Page 3 of 27
ASC_Soft termination_(SH)_020O_DS
Jun. 2019