SBL20A100
Voltage 100V 20.0 Amp
Low VF Planar MOS Barrier Schottky Rectifier
Elektronische Bauelemente
RoHS Compliant Product
A suffix of “-C” specifies halogen free
TO-220
FEATURES
B
N
D
E
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Planar MOS Schottky technology
Low forward voltage drop
Low reverse current
High current capability
High reliability
M
P
A
C
O
High surge current capability
Epitaxial construction
J
H
L
MECHANICAL DATA
G
F
K
L
ꢀ
ꢀ
ꢀ
Case: Molded plastic
Epoxy: UL94V-0 rate flame retardant
Lead: Lead solderable per MIL-STD-202
method 208 guaranteed
Millimeter
Min.
Millimeter
ꢀ
ꢀ
ꢀ
Polarity: As Marked
Mounting position: Any
Weight: 1.98 g (Approximate)
REF.
REF.
Max.
16.51
10.67
14.75
4.90
1.45
2.92
0.76
4.5
Min.
0.7
Max.
1.78
1.02
2.69
3.43
4.09
9.65
1.45
A
B
C
D
E
F
14.22
9.65
12.50
3.56
0.51
2.03
0.31
3.5
J
K
L
M
N
O
P
0.38
2.39
2.50
3.10
8.38
0.89
1
3
2
G
H
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise s pecified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Symbol
Rating
Unit
Maximum Recurrent Peak Reverse Voltage
Working Peak Reverse Voltage
VRRM
VRSM
VDC
100
100
100
10
V
V
V
Maximum DC Blocking Voltage
Maximum Average Forward Rectified
Current
(Per Leg)
A
IF
20
(Per Device)
IFSM
120
A
Peak Forward Surge Current, 8.3 ms single half sine-wave
Voltage Rate of Chance (Rated VR)
dv/dt
10000
2
V / µs
°C /W
°C
Typical Thermal Resistance
Rθ
JC
Operating and Storage Temperature Range
TJ,TSTG
-40~150
ELECTRICAL CHARACTERISTICS
Parameter
Symbol
Typ.
Max.
0.64
0.74
0.84
-
Unit
Test Condition
IF = 3A, TJ = 25°C
0.57
0.69
0.79
0.7
-
IF = 5A, TJ = 25°C
IF = 10 A, TJ = 25°C
IF = 10 A, TJ = 125°C
TJ=25°C
Maximum Instantaneous Forward
Voltage
VF
V
0.2
10
Maximum DC Reverse Current
at Rated DC Blocking Voltage 2
Typical Junction Capacitance 1
IR
mA
pF
-
TJ=100°C
CJ
160
-
NOTES:
1. Measured at 1MHz and applied reverse voltage of 5.0V D.C.
2. Pulse Test:Pulse Width = 300 µs, Duty Cycle ≦ 2.0%.
http://www.SeCoSGmbH.com/
Any changes of specification will not be informed individually.
30-May-2013 Rev. A
Page 1 of 2