RFRX1701
Absolute Maximum Ratings
Caution! ESD sensitive device.
Parameter
Rating
Unit
V
LNA Drain Voltage (VD)
LOA Drain Voltage (VD)
RF Input Power
LO Input Power
TOPER
6
6
V
RFMD Green: RoHS compliant per EU
Directive 2011/65/EU, halogen free per
IEC 61249-2-21, <1000ppm each of
antimony trioxide in polymeric materials
and red phosphorus as a flame retardant,
and <2% antimony solder.
10
dBm
dBm
°C
15
-40 to +85
-65 to +150
Class 1A
TSTOR
°C
Exceeding any one or a combination of the Absolute
Maximum Rating conditions may cause permanent
damage to the device. Extended application of Absolute
Maximum Rating conditions to the device may reduce
device reliability. Specified typical performance or
functional operation of the device under Absolute
Maximum Rating conditions is not implied.
ESD Human Body Model
Nominal Operating Parameters
Specification
Parameter
Unit Condition
Min
Typ
Max
General Performance
RF Frequency
LO Frequency
IF Frequency
17.7
6.85
DC
26.5
15.25
4.0
GHz
GHz
GHz
dBm
dB
LO Input Drive
Conversion Gain
NF (17.7GHz to 19.7GHz)
NF (21.2GHz to 23.6GHz)
NF (24.5GHz to 26.5GHz)
IIP3
+5
13
2.5
2.7
2.9
6
dB
dB
dB
dBm
dB
Image Rejection
LO-RF Isolation
LO-IF Isolation
LO Return Loss
RF Return Loss
VD
15
40
dB
15
dB
12
dB
12
dB
3 to 5
350
V
ID
mA
NOTES: Measurements performed on part soldered on evaluation board with SMA connectors and IF ports connected to an external 90° Hybrid Combiner
and LO Power of +5dBm and at 25°C, unless otherwise stated.
IF = 2.5GHz, RF Power = -20dBm, IIP3 is measured with a 2-tone input of -23dBm power for each tone and Δf = 10MHz, Vd1 = 3V, Vd2 = 4V, Vd3 through
Vd5 = 5V, MixerBias = 0V
RF Micro Devices Inc. 7628 Thorndike Road, Greensboro, NC 27409-9421
For sales or technical support, contact RFMD at +1.336.678.5570 or customerservice@rfmd.com.
DS131025
The information in this publication is believed to be accurate. However, no responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any infringement of patents or other rights of
third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent rights of RFMD. RFMD reserves the right to change component circuitry, recommended
application circuitry and specifications at any time without prior notice.
2 of 7