DC-DC Converter
RDF25 Series
Input
Characteristic
Minimum
16
Typical
Maximum
Units
Notes & Conditions
Input Voltage Range
Input Filter
160
VDC
24 V, 37.5 V, 48 V, 72 V, 96 V & 110 V nominal inputs
Internal Pi type
Input Voltage Surge
Undervoltage Lockout
176
VDC for 100 ms
OFF at 12 V, ON at 13.8 V
ON at 3.0 VDC to 12.0 VDC or open circuit
Positive logic reference to -Vin (pin 2)
When module inhibited
Remote On/Off
(Positive Logic)
OFF at 0 VDC to 1.2 VDC or short pin 2 to pin 3
3
Standby Mode
mA
Output
Characteristic
Output Voltage
Output Trim
Minimum
Typical
Maximum
Units
VDC
%
Notes & Conditions
5
24
10
See Models and Ratings table
Initial Set Accuracy
Minimum Load
Line Regulation
Load Regulation
1.0
%
At full load
A
No minimum load required
From minimum to maximum input at full load
From 0 to full load
0.2
0.5
%
%
Recovery within 1% in less than 500 µs for a 25% load
change.
Transient Response
4
% deviation
Ripple & Noise
100
mV pk-pk
20 MHz bandwidth. Measured using external 10 µF MLCC
Zener diode clamp
Overvoltage Protection
Overload Protection
120
150
%
%
Short Circuit Protection
Maximum Capacitive Load
Temperature Coefficient
Continuous trip & restart (hiccup mode), with auto recovery
See Models and Ratings table
0.02
%/˚C
General
Characteristic
Minimum
Typical
Maximum
Units
%
Notes & Conditions
See Models and Ratings table
60 s basic isolation
At 3 kVDC
Efficiency
85
Isolation: Input to Output
Isolation Resistance
Isolation Capacitance
Switching Frequency
Power Density
3000
VDC
Ω
9
10
2000
250
pF
kHz
3
28
W/in
Mean Time Between Failure
Case Material
230
khrs
MIL-HDBK-217F, +25 °C GB
Copper case with non-conductive plastic base, UL94V-0 rated
Epoxy UL94V-0
Potting Material
Fire Protection
Designed to meet EN45545-2
PCB Pin Material
Tinned copper ø 1.0 mm brass, solder coated
Lead Free Reflow Solder Process IPC JEDEC J-STD 020D.1. 260 °C max. 1.5 mm from case. 10 s max.
0.079 (36.0)
Standard
Weight
lb (g)
0.104 (47.0)
With heatsink
www.xppower.com
2