RDA2032Z
Absolute Maximum Ratings
Caution! ESD sensitive device.
Parameter
Supply Voltage
Rating
5.5
Unit
V
Exceeding any one or a combination of the Absolute Maximum Rating conditions may
cause permanent damage to the device. Extended application of Absolute Maximum
Rating conditions to the device may reduce device reliability. Specified typical perfor-
mance or functional operation of the device under Absolute Maximum Rating condi-
tions is not implied.
DC Supply Current
228
mA
mW
dBm
°C
Power Dissipation
1054
RoHS status based on EUDirective2002/95/EC (at time of this document revision).
Max Input RF Power
Operating Temperature
Storage Temperature
Junction Temperature (TJ)
+24
The information in this publication is believed to be accurate and reliable. However, no
responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any
infringement of patents, or other rights of third parties, resulting from its use. No
license is granted by implication or otherwise under any patent or patent rights of
RFMD. RFMD reserves the right to change component circuitry, recommended appli-
cation circuitry and specifications at any time without prior notice.
-40 to +85
-40 to +150
+150
°C
°C
ESD Rating (HBM)
500 (Class 1B)
3
V
Moisture Sensitivity Level (MSL)
Specification
Parameter
Overall
Unit
Condition
Min.
Typ.
Max.
Temp=25°C, VCC=VDD=5V, VCTL=TTL Logic,
Tested With Evaluation Circuit
Frequency Range
Gain Max at 140MHz
Gain Control Range
Step Accuracy
50
1000
MHz
dBm
dB
38.8
31.5
Attenuation=0dB
0.5dB step
±(0.15+3% attenuation setting)
dB
Major state max error up to 1000MHz
Attenuation=0dB
OP1dB at 140MHz
OIP3 at 140MHz
20
42
dBm
dBm
POUT=0dBm/tone, 1MHz spacing
Control Interface
Settling Time
6
Parallel mode 6-bit
220
ns
tON, tOFF (10%/90% RF)
NF at 140MHz
3.2
-30
-25
dB
dB
dB
V
Attenuation=0dB
50 system
Input Return Loss at 140MHz
Output Return Loss at 140MHz
50 system
Amplifier Supply Voltage (VCC
)
4.75
5.0
5
5.25
Attenuator Supply Voltage (VDD
Total Supply Current
)
3.0
5.25
204
V
164
182
39
mA
Sum of currents from VDD and VCC
Thermal Resistance
°C/W
Typical RF Performance at Key Operating Frequencies
Parameter
Max Small Signal Gain
OP1dB
Unit
50MHz 140MHz 280MHz 500MHz 850MHz 1000MHz
dB
39.5
19.5
40.0
-20
38.8
20.0
42.0
-30
38.5
20.0
42.0
-20
37.8
20.0
39.5
-19
36.5
19.8
36.0
-16
36.0
19.6
35.0
-15
dBm
dBm
dB
OIP3
Input Return Loss
Output Return Loss
NF
dB
-30
-28
-23
-20
-11.5
3.3
-10
dB
3.1
3.2
3.3
3.3
3.3
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
2 of 11
DS100813