RAA788170, RAA788172, RAA788173, RAA788175, RAA788176, RAA788178 Datasheet
3. Specifications
3.1
Absolute Maximum Ratings
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such
conditions can adversely impact product reliability and result in failures not covered by warranty.
Parameter
Minimum
Maximum
Unit
VCC to GND
Input Voltages
DI
7
V
-0.3
-0.3
7
7
V
V
[1]
DE, RE
Input/Output Voltages
A, B, Y, Z
-8
13
V
RO
-0.3
V
+ 0.3
CC
Short-Circuit Duration
Y, Z
Continuous
1. If the DE or RE input voltage exceeds the VCC voltage by more than 500mV, current flows into the logic pin. The current is limited by a
340Ω resistor (so ≈ 13mA with VIN = 5V and VCC = 0V) so no damage occurs if VCC ≤ VIN ≤ 7V for short periods of time.
3.2
ESD Ratings
ESD Model/Test/Condition
Rating
±15
Unit
kV
IEC61000-4-2, Air-Gap Discharge Method - RS-485 Pins (A, Y, B, Z, A/Y, B/Z)
IEC61000-4-2, Contact Discharge Method - RS-485 Pins (A, Y, B, Z, A/Y, B/Z)
±8
kV
Human Body Model (Tested per JS-001-2017) - RS-485 Pins (A, Y, B, Z, A/Y, B/Z)
from Bus pins to GND
±15
kV
Human Body Model (Tested per JS-001-2017) - All pins
Machine Model
±7
kV
V
200
3.3
EFT Performance
EFT Test/Condition
Rating
Unit
5kHz
IEC61000-4-4 Electrical Fast Transient Immunity
- RS-485 Pins (A, Y, B, Z, A/Y, B/Z)
±3
kV
100kHZ
3.4
Recommended Operating Conditions
Parameter
Minimum
Maximum
Unit
Ambient Temperature
-40
+85
°C
R15DS0017EU0101 Rev.1.01
Oct 2, 2023
Page 6