RAA23014x RAA23015x
Pin Function
RAA23014x (1CHDCDC + Battery backup)
Pin No.
Symbol
VOUT
I/O
Function
1
I
I
VOUT feedback
2
3
4
FB
Feedback resistor connection
Battery connection
VBB_IN
VBB_OUT
I
O
Backup voltage output
Device enable
5
EN
I
EN=“L” : Disable (shutdown)
EN=”H” : Enable (operation)
Auto PFM mode ON/OFF
x_AutoPFM=”L” : Auto PFM mode (change automatically)
6
7
x_AutoPFM
VREG
I
PFM mode at light load
PWM mode at heavy load
x_AutoPFM=“H” : PWM mode (fixed)
Internal power supply output
O
(Connect 1uF capacitor between VREG and GND)
8
GND
GND
GND
GND
LX
I/O
I/O
I/O
I/O
O
Ground
9
Ground
10
11
12
13
14
15
16
Ground
Ground
Inductor connection
Boost
VIN
I
I
Boot strap input (Connect 0.1uF capacitor between LX and Boost)
Power supply
GND
GND
I/O
I/O
Ground
Ground
RAA23015x (1CHDCDC)
Pin No.
Symbol
VOUT
I/O
Function
VOUT feedback
1
I
I
2
FB
Feedback resistor connection
Internal power supply output
(Connect 1uF capacitor between VREG and GND)
Device enable
3
VREG
O
4
EN
I
EN=“L” : Disable (shutdown)
EN=”H” : Enable (operation)
Ground
5
6
7
8
GND
LX
I/O
O
Inductor connection
Boost
VIN
I
I
Boot strap input (Connect 0.1uF capacitor between LX and Boost)
Power supply
Page 5 of 25
R18DS0019EJ0100 REV.1.00
Sep.09.2015