200W Quad Output with PFC Function
QP-200 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
CH1,2 can be adjustable from -5~+10%
With power good and fail signal output(Optional)
Built-in remote sense function for CH1,2
100% full load burn-in test
CH4 can set to positive after consult us before delivery(Optional)
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
..
SPECIFICATION
MODEL
QP-200D
QP-200F
QP-200-3A
OUTPUT NUMBER
CH1
5V
CH2
12V
4A
CH3
24V
3A
CH4
-12V
0.7A
CH1
5V
CH2
15V
3A
CH3
24V
3A
CH4
-15V
0.7A
CH1
5V
CH2
CH3
12V
6A
CH4
-5V
DC VOLTAGE
3.3V
15A
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK CURRENT
15A
15A
15A
0.7A
3 ~ 20A 0 ~ 6A
203.4W
0.4 ~ 5A 0 ~ 1A
3 ~ 20A 0 ~ 5A
202.5W
0.4 ~ 5A 0 ~ 1A
3 ~ 20A 0 ~ 20A 0.5 ~ 8A 0 ~ 1A
200W
Note.4 20A
7A
6A
1A
20A
6A
6A
1A
20A
20A
8A
1A
OUTPUT
RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p 150mVp-p 150mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
CH2: 11.4 ~ 13.2V CH1: 4.75 ~ 5.5V
CH2: 14.25 ~ 16.5V CH1: 4.75 ~ 5.5V
CH2: 3.14 ~ 3.63V
+8,-10% 6.0%
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
1.0%
2.0%
+10,-6% 6.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
+10,-6% 6.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
1.0%
2.0%
2.0%
6.0%
1.0%
2.0%
2.0%
6.0%
1.0%
2.0%
2.0%
6.0%
1.0%
2.0%
800ms, 50ms at full load
24ms at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.6 90 ~ 264VAC
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
47 ~ 63Hz
PF>0.95/230VAC
75%
PF>0.98/115VAC at full load
75%
72%
INPUT
3.5A/115VAC
COLD START 30A
<2mA / 240VAC
2A/230VAC
LEAKAGE CURRENT
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
CH1:5.75 ~ 6.75V CH2:13.8 ~ 16.2V CH1: 5.75 ~ 6.75V
CH2:17.25 ~ 20.25V CH1:5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
95 (TSW1) detect on heatsink of Q1,Q2 power transistor
OVERLOAD
CH2:3.8 ~ 4.4V
PROTECTION
OVER VOLTAGE
5
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
10ms/1ms
FUNCTION
POWER GOOD / POWER FAIL(OPTIONAL)
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
0.03%/ (0~50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 5)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
160.6K hrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
PACKING
215*115*50mm (L*W*H)
1.2Kg; 12pcs/15.4Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
6. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-200-SPEC 2010-10-18