描述
U-GAGE K50U Ultrasonic Sensor

QM42VT2 数据手册

 浏览型号QM42VT2的Datasheet PDF文件第1页浏览型号QM42VT2的Datasheet PDF文件第2页浏览型号QM42VT2的Datasheet PDF文件第3页浏览型号QM42VT2的Datasheet PDF文件第5页浏览型号QM42VT2的Datasheet PDF文件第6页 
®
Sure Cross U-GAGE K50U Ultrasonic Sensor  
K50UX1CRA Performance  
Discrete Inputs  
One Sinking  
Sensing range: 300 mm to 3 m (11.8 in to 118 in)  
Ultrasonic frequency: 114 kHz  
Temperature effect: 0.02% of distance/°C  
Resolution: 0.1% of distance (1.5 mm minimum)  
Rating: 3 mA max current at 30 V dc  
ON Condition: Less than 0.7 V  
OFF Condition: Greater than 2 V or open  
K50UX1ARA Performance  
Discrete Outputs  
Sensing range: 100 mm to 1 m (3.94 in to 39.4 in)  
Ultrasonic frequency: 224 kHz  
Temperature effect: 0.02% of distance/°C  
Resolution: 0.1% of distance (1.5 mm minimum)  
Discrete Outputs. One NMOS Sinking (Not used)  
Discrete Output Rating: Less than 10 mA maximum current at 30 V; ON-  
State Saturation: Less than 0.7 V at 20 mA  
Discrete Output ON Condition. Less than 0.7 V  
Discrete Output OFF Condition. Open  
Communication Hardware  
1-wire serial interface  
Baud Rates: 9.6k, 19.2k (default), or 38.4k  
Data Format: 8 data bits, No parity (default), even parity, or odd parity  
1 stop bit  
Communication Protocol  
Compatible Nodes  
Sure Cross DX80 Sensor Node 1-Wire Serial Interface  
900 MHz Models  
DX80N9X1S-P6  
2.4 GHz Models  
DX80N2X1S-P6  
Communications Line  
Level Receive ON: Greater than 2 V  
Level Receive OFF: Less than 0.7 V  
Level Transmit ON: 2.7 to 3 V  
DX80N9X6S-P6  
DX80DR9M-H6 and -H6L  
DX80N9Q45U  
DX80N2X6S-P6  
DX80DR2M-H6 and -H6L  
DX80N2Q45U  
Level Transmit OFF: 0 V (pulldown resistor of 10 kOhm)  
Environmental Rating1  
Vibration and Mechanical Shock  
Leakproof design, rated IEC IP67 (NEMA 6)  
All models meet MIL-STD-202F, Method 201A (Vibration: 10 Hz to 60 Hz  
maximum, 0.06 inch (1.52 mm) double amplitude, 10G maximum  
acceleration) requirements. Also meets IEC 60947-5-2 (Shock: 30G 11 ms  
duration, half sine wave) requirements.  
Operating Conditions  
–40 °C to +70 °C (–40 °F to +158 °F)  
95% at +50 °C maximum relative humidity (non-condensing)  
Certifications  
Dimensions  
59.5 mm  
[2.34”]  
19 mm  
[0.75”]  
20 mm  
[0.79]  
27.5 mm  
[1.08”]  
50 mm  
[1.97”]  
M30 x 1.5  
1 1/4-11.5 NPT  
All measurements are listed in millimeters [inches], unless noted otherwise.  
1
Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.  
www.bannerengineering.com - Tel: +1-763-544-3164  
4
P/N 191599 Rev. F