QLS30 DC-DC Series Data Sheet  
30A Quarter-Brick Converter  
Industrial Standard Positive Trim (suffix –T)  
The -T option units trim up with a resistor from the TRIM  
pin to the +Sense pin and trim down with a resistor from  
the TRIM pin to the –Sense pin as shown in the Figure 9.  
Safety Considerations  
The QLS30 Series converters feature 1500 Volt DC  
isolation from input to output.  
The input-to-output  
resistance is greater than 10MOhm. These converters are  
provided with Basic insulation between input and output  
circuits according to all IEC60950 based standards.  
Nevertheless, if the system using the converter needs to  
receive safety agency approval, certain rules must be  
followed in the design of the system. In particular, all of  
the creepage and clearance requirements of the end-use  
safety requirements must be observed. These documents  
include UL60950, CSA60950-00 and EN60950, although  
other additional requirements may be needed for user’s  
specific applications.  
The QLS30 Series converters have no internal fuse. An  
external fuse must be provided to protect the system from  
catastrophic failure, as illustrated in Figure 7. The fuse  
with a rating of 4A or less is recommended. The user can  
select a lower rating fuse based upon the highest inrush  
transient at the maximum input voltage and the maximum  
input current of the converter at the minimum input voltage.  
Both input traces and the chassis ground trace (if  
applicable) must be capable of conducting a current of 1.5  
times the value of the fuse without opening. The fuse must  
not be placed in the grounded input line, if any.  
Figure 9. QLS30 Series Positive Trim Schematic  
The equations below determine the trim resistor value  
required to achieve a ΔV change in the output voltage.  
In order for the output of the QLS30 Series converter to be  
considered as SELV (Safety Extra Low Voltage) or TNV-1,  
according to all IEC60950 based standards, one of the  
following requirements must be met in the system design:  
Vout(100+ ΔV%) 100+ 2ΔV%  
R =5.11  
,kΩ  
UP  
1.225ΔV%  
ΔV%  
100  
RDOWN = 5.11  
2 , kΩ  
If the voltage source feeding the module is SELV or  
TNV-2, the output of the converter may be grounded  
or ungrounded.  
If the voltage source feeding the module is ELV, the  
output of the converter may be considered SELV only  
if the output is grounded per the requirements of the  
standard.  
If the voltage source feeding the module is a  
Hazardous Voltage Secondary Circuit, the voltage  
source feeding the module must be provided with at  
least Basic insulation between the source to the  
converter and any hazardous voltages. The entire  
system, including the QLS30 converter, must pass a  
dielectric withstand test for reinforced insulation.  
Design of this type of systems requires expert  
engineering and understanding of the overall safety  
requirements and should be performed by qualified  
personnel.  
ΔV %  
For QLS30ZY use the following equations.  
Vout(100+ ΔV%)  
1.225ΔV%  
R =5.11  
,KΩ  
UP  
100  
1
RDOWN = 5.11  
,KΩ  
2ΔV % 2  
where ΔV% is the output voltage change expressed in  
percents of the nominal output voltage, Vout.  
Notes:  
1. When the output voltage is trimmed up, the output power  
from the converter must not exceed its maximum rating. The  
power is determined by measuring the output voltage on the  
output pins, and multiplying it by the output current.  
Thermal Considerations  
The QLS30 Series converters are designed for both  
natural and forced convection cooling. The maximum  
allowable output current of the converters is determined by  
meeting the derating criteria of all electronic components  
used in the power supplies. An example of the derating  
criteria for the semiconductor junction temperature is not to  
exceed 120°C to provide reliable long-term operation of the  
converters.  
2. In order to avoid creating apparent load regulation  
degradation, it is important that the trim resistors are  
connected directly to the remote sense pins, and not to the  
load or to traces going to the load.  
3. The QLS30 Series converters will trim down further than the  
10% limit. In general, this is permissible. The user must  
confirm that the results are acceptable in the application.  
MCD10053 Rev. 1.0  
Page 7 of 9  
www.power-one.com  

与QLS30ZANT相关器件

型号 品牌 描述 获取价格 数据表
QLS30ZA-NT BEL 暂无描述

获取价格

QLS30ZANT8 BEL 1-OUTPUT DC-DC REG PWR SUPPLY MODULE, QUARTER BRICK PACKAGE-8

获取价格

QLS30ZA-NT8 BEL DC/DC CONVERTER 1.5V 45W

获取价格

QLS30ZANT9 BEL 1-OUTPUT DC-DC REG PWR SUPPLY MODULE, QUARTER BRICK PACKAGE-8

获取价格

QLS30ZA-NT9 BEL DC/DC CONVERTER 1.5V 45W

获取价格

QLS30ZAT BEL 1-OUTPUT DC-DC REG PWR SUPPLY MODULE, QUARTER BRICK PACKAGE-8

获取价格