QHS DC-DC Series Data Sheet  
1. When the output voltage is trimmed up, the output power from  
the converter must not exceed its maximum rating. The power is  
determined by measuring the output voltage on the output pins,  
and multiplying it by the output current.  
source feeding the module must be provided  
with at least Basic insulation between the  
source to the converter and any hazardous  
voltages. The entire system, including the  
2. In order to avoid creating apparent load regulation degradation, it  
is important that the trim resistors are connected directly to the  
remote sense pins, and not to the load or to traces going to the  
load.  
QHS converter, must pass  
a
dielectric  
withstand test for Reinforced insulation.  
Design of this type of systems requires expert  
engineering and under-standing of the overall  
safety requirements and should be performed  
by qualified personnel.  
3. The QHS Series converters will trim down further than the 10%  
limit. In general, this is permissible. The user must confirm that  
the results are acceptable in the application.  
Thermal Considerations  
Safety Considerations  
The QHS Series converters are designed for  
The QHS Series converters feature 1500 VDC isolation  
from input to output. The input to output resistance is  
greater than 10 M. These converters are provided  
with Basic insulation between input and output circuits  
according to all IEC60950 based standards.  
Nevertheless, if the system using the converter needs  
to receive safety agency approval, certain rules must be  
followed in the design of the system. In particular, all of  
the creepage and clearance requirements of the end-  
use safety requirements must be observed. These  
documents include UL60950 - CSA60950-00 and  
EN60950, although other or additional requirements  
may be needed for specific applications.  
natural or forced convection cooling.  
The  
maximum allowable output current of the  
converters is determined by meeting the derating  
criteria for all components used in the converters.  
For example, the maximum semiconductor  
junction temperature is not allowed to exceed  
120 °C to ensure reliable long-term operation of  
the converters.  
Contact Power-One for the  
complete list of the derating criteria.  
The graphs in Figures 11-14 show the maximum  
output current of the QHS Series converters at  
different ambient temperatures under both natural  
and forced (longitudinal airflow direction, from pin  
1 to pin 3) convection.  
The QHS Series converters have no internal fuse. The  
external fuse must be provided to protect the system  
from catastrophic failure as shown in Figure 7. The  
user can select a fuse based upon the highest inrush  
transient at the maximum input voltage and the  
maximum input current of the converter, which occurs  
at the minimum input voltage. Both input traces and the  
chassis ground trace (if applicable) must be capable of  
conducting a current of 1.5 times the value of the fuse  
without opening. The fuse must not be placed in the  
grounded input line, if any.  
For example, from Figure 11, the QHS40ZE  
operating at 55 °C can deliver up to 18 A reliably  
with 100 LFM forced air, while up to 25 A reliably  
with 400 LFM forced air.  
12  
10  
8
In order for the output of the QHS Series converter to  
be considered as SELV (Safety Extra Low Voltage) or  
TNV-1, according to all IEC60950 based standards, one  
of the following requirements must be met in the system  
design:  
6
0
4
100LFM  
200LFM  
2
300LFM  
400LFM  
If the voltage source feeding the module is SELV or  
TNV-2, the output of the converter may be  
grounded or ungrounded.  
0
25 30 35 40 45 50 55 60 65 70 75 80 85  
Ambient Temperature (C)  
Figure 11. QHS12ZH (12V) Derating Curves  
If the voltage source feeding the module is ELV, the  
output of the converter may be considered SELV  
only if the output is grounded per the requirements  
of the standard.  
If the voltage source feeding the module is a  
Hazardous Voltage Secondary Circuit, the voltage  
DEC 09, 2004 revised to APR 12, 2006  
Page 8 of 10  
www.power-one.com  

与QHS40ZDN-T8相关器件

型号 品牌 描述 获取价格 数据表
QHS40ZDN-T9 BEL DC-DC Regulated Power Supply Module, 1 Output, 10W, Hybrid, PACKAGE-8

获取价格

QHS40ZE BEL DC-DC Regulated Power Supply Module, 1 Output, 13W, Hybrid, PACKAGE-8

获取价格

QHS40ZE8 BEL DC-DC Regulated Power Supply Module, 1 Output, 13W, Hybrid, PACKAGE-8

获取价格

QHS40ZEN8 BEL DC-DC Regulated Power Supply Module, 1 Output, 13W, Hybrid, PACKAGE-8

获取价格

QHS40ZEN9 BEL DC-DC Regulated Power Supply Module, 1 Output, 13W, Hybrid, PACKAGE-8

获取价格

QHS40ZENT BEL 1-OUTPUT DC-DC REG PWR SUPPLY MODULE, QUARTER BRICK PACKAGE-8

获取价格