Issue: 01
Date: 2003-03-10
Specification
Filter type :
QF1400
Front End ( Antenna) Crystal Filter
Parameter
min. typ. max. Unit
Condition
Frequency range
60
90
MHz
kHz
kHz
dB
Standard frequencies
Pass bandwidth
±7,5
@ 3 dB
@ fo ± 5 kHz
Pass band ripple
1
4
Insertion / transducer attenuation
Shape factor SF
dB
… dB / … dB
Selectivity
±30 kHz
±60 kHz
kHz
@ 20 dB
@ 45 dB
@ … dB
Spurious response attenuation
Ultimate attenuation
Termination
50
70
dB
dB
Input
50 // 0
50 // 0
Ω // pF
Ω // pF
µs
Output
Group delay
Input Power
nominal
0,1
mW
mW
Maximum (for 10 sec)
Operating temperature range
Operable temperature range
Storage temperature range
1
0
-20
-40
+60 °C
+70 °C
+85 °C
Enclosure (see drawing)
61 x 26,2 x 26,2
mm
Terminals
BNC, N or SMA
female
gram
Option I
Weight
Packing
bulk
ESD Sensitivity
1500
V
HBM as in IEC 61000-4-
2
Notes:
1. Terminology and test conditions are according to IEC standard IEC60368-1, unless otherwise stated
Ordering Code:
Model (Specification)
Option I Frequency [MHz]
BNC 66,250
QF1400
Products
wwwAXTAL.com
Buchfinkenweg 8
DE-74931 Lobbach
Germany
page 1(2)
phone: +49 (6226) 9719689
fax: +49 (6226) 970133