45-56Vdc Input; 10.4Vdc, 78.0A, 810W Output
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Remote On/Off Signal Interface
(VIN=VIN, min to VIN, max , Signal referenced to VIN- terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low Specification
On/Off Thresholds:
Remote On/Off Current – Logic Low (Vin =56V)
All
All
All
Ion/off
Von/off
Von/off
200
0.8
μA
Vdc
Vdc
-0.3
2.4
Logic Low Voltage
Logic High Voltage – (Typ = Open Collector)
14.5
Logic High maximum allowable leakage current
(Von/off = 2.4V)
All
All
Ion/off
130
μA
Maximum voltage allowed on On/Off pin
Von/off
14.5
Vdc
Turn-On Delay and Rise Times (IO=IO, max
)
All w/o “P’
option
All w/o “P”
option
All w/ “P’
option
All w/ “P”
option
Tdelay, Enable with
Vin
30
5
ms
ms
ms
ms
Tdelay=Time until VO = 10% of VO,set from either application of Vin
with Remote On/Off set to On (Enable with Vin); or operation of
Remote On/Off from Off to On with Vin already applied for at
least 30 milli-seconds (Enable with on/off).
Tdelay, Enable with
on/off
Tdelay, Enable with
40*
15*
Vin
* Increased Tdelay due to startup for parallel modules.
Tdelay, Enable with
on/off
All w/o
“P”
option
All w/ “P’
option
Trise=Time for VO to rise from 10% to 90% of VO,set, For CO
Trise
15
ms
>4500uF, IO must be < 50% IO, max during Trise
.
* Increased Trise when pre-bias Vo exists at startup for parallel
modules.
Trise
40*
ms
Vdc
Output Overvoltage Protection
Overtemperature Protection
(See Thermal Considerations, Fig. 16)
Input Undervoltage Lockout
Turn-on Threshold
All
VO,limit
12.0
16.0
All
Tref
128
°C
41
39
2
44
41
45
43
Vdc
Vdc
Vdc
Turn-off Threshold
Hysteresis
Input Overvoltage Lockout
Turn-off Threshold
62
60
Vdc
Vdc
Turn-on Threshold
January 15, 2014
©2012 General Electric Company. All rights reserved.