QAE100
ENVIRONMENTAL SPECIFICATIONS
Parameter
Conditions
Min.
Typ.
Max.
Unit
ꢀ
ꢀ
Operating base-plate temperature
Over temperature protection
Storage temperature range
Thermal impedance (2)
-40
+100
+110
-55
+125
ꢀ
Without Heat-sink
9
Vertical direction by natural
convection (20LFM)
Mount on 2U iron base-plate
With 0.24" Height Heat-sink
With 0.5" Height Heat-sink
2.8
7.1
5.5
ꢀ/W
Thermal shock
Vibration
Relative humidity
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI (3)
Conditions
Level
Class A
Class B
EN55022
Air ± 8kV
Contact ± 6kV
20 V/m
± 2kV
EN55024:±2kV
10 Vr.m.s
ESD
EN61000-4-2
Perf. Criteria A
Radiated immunity
Fast transient (4)
Surge (4)
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Conducted immunity
Note:
1. Input source impedance: The power modules will operate as specifications without external components, assuming that the source voltage has a
very low impedance and reasonable input voltage regulation. Highly inductive source impedances can affect the stability of the power module.
Since real-world voltage source has finite impedance, performance can be improved by adding external filter capacitor.
Recommended Nippon Chemi-con KY series, 100µF/100V.
2. The heat-sink is optional and P/N: 7G-0029A-F , 7G-0030A-F , 7G-0031A-F , 7G-0032A-F. Please refer to heat-sink selection guide.
3. The standard modules meet EMI Class A or Class B with external components. For further information, please contact with P-DUKE.
4. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
Recommended 2 pcs of aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) to connect in parallel.
5. BASE-PLATE GROUNDING: When connect two screw bolts to shield plane, the EMI could be reduced.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
QAE100-48S05 Derating Curve
QAE100-48S05 Derating Curve
With 0.24” Height Heat-sink
QAE100-48S05 Derating Curve
With 0.5” Height Heat-sink
QAE100-48S05 Efficiency vs. Input Voltage
QAE100-48S05 Efficiency vs. Output Load
www.PDUKE.com
3
2014/10/03