Q2S30 Series – 30A Quarter-Brick DC/DC Converter
48, 24V Input
Data Sheet
3.3V, 2.5V, 2.0V, 1.8V, 1.5V Output
Output Specifications
All specifications apply over specified input voltage, output load and temperature range, unless otherwise
noted.
Parameter
Output Voltage Setpoint Accuracy
Output Current*
Conditions/Description
Vin=Vin.nom, Full Load
Min
-1
0
Nom
Max
1
30
±5
Units
%Vout
ADC
mV
Line Regulation
Vin min to Vin max,
Iout max
Vin=Vnom, Iout min to
Iout max
±2
±2
Load Regulation
±5
3
mV
Total Output Voltage Regulation
Over all input voltage, load,
and temperature conditions
-3
%Vout
%Vout
Remote Sense Headroom***
Dynamic Regulation
Peak Deviation
10%
50-75% load step change
di/dt = 5 A/μs
160
100
mV
µs
Settling Time
to 1% error band
Admissible Load Capacitance
Output Current Limit Threshold**
Switching Frequency
Over voltage Protection,
Non Latching
Iout max, Nom Vin
Vout ≤0.97Vout nom
30,000
40
µF
33
115
-20
36
435
122
ADC
kHz
%Vout
Over all input voltage and
load conditions
127
+10
Trim Range
Iout max, Vin=Vnom
%Vout
** Overcurrent protection is non-latching with auto recovery.
*** Vout can be increased up to 10% via the sense leads or up to 10% via the trim function, however total
output voltage trim from all sources should not exceed 10% of Vout (NOM) in order to ensure specified
operation of over-voltage protection circuitry.
Feature Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise
noted.
Parameter
Shutdown (ON/OFF)
Negative Logic
- Converter ON
- Converter OFF
Positive Logic
- Converter ON
- Converter OFF
Overtemperature
Protection
Conditions/Description
Min
Nom
Max
Units
On/Off signal is low – converter is ON
Low logic range
High logic range
On/Off signal is low –converter is OFF
High logic range
-20
2.4
0.8
20
VDC
VDC
2.4
-20
20
0.8
VDC
VDC
°C
Low logic range
Shut down
118
REV. JUN 17, 2002