DESIGN CONSIDERATIONS
1) Requirement on output load
To ensure this module can operate efficiently and reliably, During operation, the minimum output load could not be less than 10% of the full load.
If the actual output power is very small, please connect a resistor with proper resistance at the output end in parallel to increase the load, or use our
company’s products with a lower rated output power.
2) Overload Protection
Under normal operating conditions, the output circuit of these products has no protection against overload. The simplest method is to connect a
self-recovery fuse in series at the input end or add a circuit breaker to the circuit.
Input Fuse Selection Guide
48VDC Input Models
24VDC Input Models
1000mA slow-Blow Type
500mA slow-Blow Typ
3) Recommended circuit
All the PWA_(M)D-3W & PWB_(M)D-3W Series have been tested according to the following recommended testing circuit before leaving factory.
This series should be tested under load (see Figure 4).
If you want to further decrease the input/output ripple, you can increase a capacitance properly or choose capacitors with low ESR (see Figure 4). If
the capacitance is too big, a startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest
capacitance of its filter capacitor must less than the Max. Capacitive Load. If you want to use the products in high EMI, please choose our metal
packaged products (PWA_MD-3W&PWB_MD-3W).
General: Cin: 24V&48V
10μF~47μF
Cout: 10μF/100mA
Dual Output
Vin
+Vo
0V
Cout
Cout
Cin
DC
DC
DC
DC
GND
-Vo
Single Output
Vin
+Vo
0V
Cout
Cin
GND
(Figure 4)
4) Input current
Nominal input voltage range.The input current of the power supply must be sufficient to the startup current (Ip) of the DC/DC module(Figure 5).
General: Ip ≤1.4*Iin-max
Ip
Input Voltage
Range
Input Voltage (V)
(Figure 5)
5) Cannot use in parallel and hot swap
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.Operation under minimum load will not damage the converter;
However, they may not meet all specification listed.
2. Max. Capacitive Load tested at input voltage range and full load.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
4. In this datasheet, all the test methods of indications are based on our corporate standards.
5. All characteristics are for listed model only, non-standard models may perform differently, please contact our technical person for more detail.
6. Contact us for your specific requirement.
7. Specifications subject to change without prior notice.
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China.
Tel: 86-20-28203030
Fax:86-20-38601272
Http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by MORNSUN
PWA_(M)D-3W&PWB_(M)D-3W A/3-2012 Page 5 of 5