PS/L Series
PERFORMANCE CHARACTERISTICS
ꢀ
Test Conditions : Conform to IEC 60384-1
TEST CONDITION
ITEM
PERFORMANCE
Operating temperature
Rated voltage (V.dc)
Derated voltage (V.dc)
Surge voltage (V.dc)
–55℃ to +105
℃
Derated voltage at 85℃ at more
2.5V
2V
4V
6.3V
5V
10V
8V
16V
12.8V
20V
20V
16V
23V
25V
at 85℃
3.3V
5.2V
20V
29V
at 105℃
Rated voltage 2.5 to 16V: at 85℃
3.3V
8V
13V
Rated voltage over 20V: at 15 to 35℃
Capacitance
2.2
Ȑ
F to 1000
ȐF
at 120 Hz
Capacitance tolerance
20%
Voltage:
DC Leakage Current (L.C)
Dissipation Factor
0.1C • V(
Ȑ
A) or 3
Ȑ
A (J case:10 A) , whichever is greater
Ȑ
Rated voltage for 5min.
Refer to Standard Ratings
Refer to Standard Ratings
DF(%)
at 120 Hz
at 100 kHz or 300 kHz
Equivalent Series Resistance
refer to STANDARD RATINGS
Capacitance change
L.C
Temperature : 85 2℃
Applied voltage : Surge voltage
Series resistance : 33 ohm
Duration of surge : 30 5 sec
Time between surge : 5.5min.
Number of cycle : 1000
Lower than initial
specification
Lower than initial
specification
Refer to Standard Ratings
Surge voltage test
Lower than initial
specification
Step 1: 25 2℃
–55
℃
from 0 to –20%
from 0 to +50%
————
Characteristic
at high and low
temperature
0
Step 2: –55–3
℃
Step 3: 25 2℃
Lower than 1.5 times
Lower than 10 times
initial specification
0
+105
℃
Step 4: 105–3
℃
initial specification
Parts shall be temperature cycled
over a temperature range of –55 to
+105℃, five times continuously as
follow.
Rapid change of
temperature
Lower than initial
specification
Lower than initial
specification
Step 1: –55–03℃, 30 3min.
Refer to Standard Ratings
Step 2: room temp. , 10 to 15min.
Step 3: 105–03℃, 30 3min.
Step 4: room temp, 10 to 15min.
Resistance to Soldering
heat
Lower than 1.3 times initial
specification
Lower than initial
specification
Reflow soldering method 240℃,
Refer to Standard Ratings
from +30% to –20%
10 sec.Max.
*1
at 40℃
Lower than 1.5 times initial
specification
Lower than initial
specification
at 90 to 95% RH
500 hour
Damp heat
at 85℃
Lower than 1.5 times initial
specification
Lower than initial
specification
at rated voltage
1000 hour
Refer to Standard Ratings
Refer to Standard Ratings
Endurance I
Endurance II
Failure Rate
at 105℃
Lower than 3 times initial
specification
Lower than initial
specification
at Derated voltage
1000 hour
at 85℃: rated voltage
at 105℃: derated voltage
1000 hour
λ0 = 1% / 1000 hour
Strength : 4.9N
Time : 10 0.5sec.
(two directions)
Visual:
Terminal Strength
There shall be no evidence of mechanical damage
at 100 kHz or 300 kHz
Permissible ripple current
Others
Refer to Ratings Table
Conform to IEC60384–1
refer to STANDARD RATINGS
Conform to IEC60384–1
ꢀꢁꢂꢃꢄꢅꢆꢅꢇꢃꢈꢉꢃꢈꢊꢅꢃꢋꢌꢍꢅꢃꢎꢏꢃꢐꢑꢒꢓꢔꢕꢃꢒꢑꢃꢖꢕꢗꢑꢘꢃꢑꢅꢉꢙꢌꢋꢌꢚꢛꢈꢉꢇꢜꢏꢝꢃ!ꢉ"#ꢈꢛ#ꢍꢜ$ꢁ%ꢃꢄꢅ ꢃꢉ'ꢃ*ꢉ+-ꢅꢇꢛ#ꢍꢜ$/%ꢃꢓꢅ4ꢋꢅꢇꢌꢈ"ꢇꢅꢃꢌ#-ꢃꢈꢛ4ꢅꢟ
Reference : Derated voltage (85 to 105°C)
[UR] – [UC]
[UT] = [UR] –
(T–85)
20
[UT] : Derated voltage at operating temperature
[UR] : Rated voltage
[UC] : Derated voltage at 105°C
T
: Operating temperature
13
●All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
●Please request for a specification sheet for detailed product data prior to the purchase.
●Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
9653TCAVOL14E1109E0