E
2
Technical Specification  
EN/LZT 146 384 R4A  
May 2013  
PKB 4000B series Intermediate Bus Converters
Input 36-75 V, Output up to 40 A / 252 W  
© Ericsson AB  
MTBF (mean value) for the PKB-B series = 3.4 Mh.  
MTBF at 90% confidence level = 2.9 Mh  
Compatibility with RoHS requirements  
Ordering Information  
Product program  
PKB 4201B PI  
PKB 4204B PI  
PKB 4207LB PI  
PKB 4207KB PI  
Output  
5 V, 40 A / 200 W  
12 V, 20 A / 240 W  
13 V, 20 A / 252 W  
14 V, 10 A / 140 W  
The products are compatible with the relevant clauses and  
requirements of the RoHS directive 2011/65/EU and have a  
maximum concentration value of 0.1% by weight in  
homogeneous materials for lead, mercury, hexavalent  
chromium, PBB and PBDE and of 0.01% by weight in  
homogeneous materials for cadmium.  
Product number and Packaging  
PKB4XXXB PI n1n2n3n4n5n6  
n1 n2 n3  
Options  
Mounting  
n4  
n5  
n6  
Exemptions in the RoHS directive utilized in Ericsson  
Power Modules products are found in the Statement of  
Compliance document.  
Remote Control logic  
Baseplate  
Ericsson Power Modules fulfills and will continuously fulfill  
all its obligations under regulation (EC) No 1907/2006  
concerning the registration, evaluation, authorization and  
restriction of chemicals (REACH) as they enter into force  
and is through product materials declarations preparing for  
the obligations to communicate information on substances  
in the products.  
Increased stand-off  
Pin length  
Delivery package information  
Options  
n1  
Description  
PI  
SI  
Through hole  
Surface mount  
Quality Statement  
The products are designed and manufactured in an  
industrial environment where quality systems and methods  
like ISO 9000, Six Sigma, and SPC are intensively in use to  
boost the continuous improvements strategy. Infant  
mortality or early failures in the products are screened out  
and they are subjected to an ATE-based final test.  
Conservative design rules, design reviews and product  
qualifications, plus the high competence of an engaged  
work force, contribute to the high quality of the products.  
n2  
n3  
Negative *  
Positive  
P
Open frame *  
HS Baseplate  
n4  
n5  
M
Increased stand-off  
5.30 mm *  
3.69 mm  
4.57 mm  
LA  
LB  
Warranty  
Warranty period and conditions are defined in Ericsson  
Power Modules General Terms and Conditions of Sale.  
n6  
/B  
Tray  
Example: a standard through hole, positive logic, baseplate  
with increased stand-off short pin product would be  
PKB4204BPIPHSMLA.  
Limitation of Liability  
Ericsson Power Modules does not make any other  
warranties, expressed or implied including any warranty of  
merchantability or fitness for a particular purpose  
(including, but not limited to, use in life support  
applications, where malfunctions of product can cause  
injury to a person’s health or life).  
* Standard variant (i.e. no option selected).  
General Information  
Reliability  
The failure rate () and mean time between failures  
(MTBF= 1/) is calculated at max output power and an  
operating ambient temperature (TA) of +40°C. Ericsson  
Power Modules uses Telcordia SR-332 Issue 2 Method 1 to  
calculate the mean steady-state failure rate and standard  
© Ericsson AB 2013  
The information and specifications in this technical  
specification is believed to be correct at the time of  
publication. However, no liability is accepted for  
inaccuracies, printing errors or for any consequences  
thereof. Ericsson AB reserves the right to change the  
contents of this technical specification at any time without  
prior notice.  
deviation ().  
Telcordia SR-332 Issue 2 also provides techniques to  
estimate the upper confidence levels of failure rates based  
on the mean and standard deviation.  
Mean steady-state failure  
Std. deviation,   
37.1 nFailures/h  
293 nFailures/h  

与PKB4201BSIHSM/B相关器件

型号 品牌 描述 获取价格 数据表
PKB4201BSIHSMLA/B ERICSSON DC-DC Regulated Power Supply Module, 1 Output, 204W, Hybrid, ROHS COMPLIANT PACKAGE-5

获取价格

PKB4201BSIHSMLB/B ERICSSON DC-DC Regulated Power Supply Module, 1 Output, 204W, Hybrid, ROHS COMPLIANT PACKAGE-5

获取价格

PKB4201BSIM/B ERICSSON DC-DC Regulated Power Supply Module, 1 Output, 204W, Hybrid, ROHS COMPLIANT PACKAGE-5

获取价格

PKB4201BSIMLA/B ERICSSON DC-DC Regulated Power Supply Module, 1 Output, 204W, Hybrid, ROHS COMPLIANT PACKAGE-5

获取价格

PKB4201BSIMLB/B ERICSSON DC-DC Regulated Power Supply Module, 1 Output, 204W, Hybrid, ROHS COMPLIANT PACKAGE-5

获取价格

PKB4201BSIPHSM/B ERICSSON DC-DC Regulated Power Supply Module, 1 Output, 204W, Hybrid, ROHS COMPLIANT PACKAGE-5

获取价格