Ordering information
AC-DC Power Supplies Enclosed Type
PJ
A
300
F
-O -O
5 6
PJA300F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-06-472
R
*6
6Optional
C: with Coating
G: Low leakage current
V : External potentiometer for
output voltage adjustment
R : Remote on/off
(Required external power source)
F4: Low speed fan
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
See 6.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
MODEL
PJA300F-5
PJA300F-12
PJA300F-15
PJA300F-24
PJA300F-36
PJA300F-48
VOLTAGE[V]
AC85 - 264 1f(Output derating is required at AC85V - 100V. Refer to “Derating” and instruction manual 1.1, 3)
ACIN 100V 3.5typ (Io=100%) 3.9typ (Io=100%)
CURRENT[A]
ACIN 115V 3.0typ (Io=100%) 3.3typ (Io=100%)
ACIN 230V 1.5typ (Io=100%) 1.7typ (Io=100%)
FREQUENCY[Hz]
EFFICIENCY[%]
50 / 60 (47 - 63)
ACIN 100V 73typ (Io=100%)
ACIN 115V 74typ (Io=100%)
ACIN 230V 77typ (Io=100%)
ACIN 100V 0.99typ (Io=100%)
ACIN 115V 0.98typ (Io=100%)
ACIN 230V 0.95typ (Io=100%)
79typ (Io=100%)
80typ (Io=100%)
82typ (Io=100%)
81typ (Io=100%)
82typ (Io=100%)
84typ (Io=100%)
82typ (Io=100%)
83typ (Io=100%)
86typ (Io=100%)
83typ (Io=100%)
83typ (Io=100%)
87typ (Io=100%)
82typ (Io=100%)
83typ (Io=100%)
86typ (Io=100%)
INPUT
POWER FACTOR
ACIN 100V 20typ (Io=100%) Ta=25Cat cold start
INRUSH CURRENT[A] ACIN 115V 20typ (Io=100%) Ta=25Cat cold start
ACIN 230V 40typ (Io=100%) Ta=25Cat cold start
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)
12 15 24
5
36
48
ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to “Derating”)
CURRENT[A]
WATTAGE[W]
ACIN 100V-264V 50
25
20
12.5
8.4
6.3
ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to “Derating”)
ACIN 100V-264V 250
300
300
300
302.4
302.4
*
3
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
48max
100max
120max
160max
150max
180max
120max
180max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
144max
150max
150max
160max
200max
240max
360max
440max
144max
192max
300max
150max
400max
200max
500max
480max
600max
192max
*
3
0 to +50C 80max
-10 to 0C 140max
0 to +50C 120max
-10 to 0C 160max
0 to +50C 50max
-10 to +50C 75max
RIPPLE[mVp-p]
*1
*1
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
*
2
20max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
300typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50
10.80 to 13.20
12.00 to 12.48
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
32.40 to 39.60
36.00 to 37.44
43.20 to 52.80
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
5.00 to 5.15
Works over 105% of rating and recovers automatically
13.80 to 16.80 17.25 to 21.00
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00
27.60 to 33.60
41.40 to 50.40
55.20 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT RC
INPUT-FG
OUTPUT RC-FG
OUTPUT-RC
Optional (Required external power source. Option -R)
*
9
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
-20 to +70C(Refer to “Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
ISOLATION
*
*
*
9
9
4
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL62368-1, C-UL (CSA62368-1), EN62368-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
8
June 25, 2020
PJA-6