Data Sheet
GE
PIM400 Series; ATCA Board Power Input Modules
-36 to -75 Vdc; 400W/10A
Features
.
-48V/10A Dual redundant input power distribution
.
3.3Vdc/3.6A & 5.0Vdc/150mA of isolated Management Power
for IPM or other housekeeping functions
.
Independent holdup capacitor charging voltage; trimmable
from 50 to 95Vdc for optimal real estate
.
.
OR’ing functionality, Inrush protection & hot swap capability
Integral EMI filter designed for the ATCA board to meet CISPR
Class B with minimal external filtering
.
Protection: Reverse polarity, under voltage, input transient
over voltage/current and temperature
.
.
.
.
.
I2C digital interface options
Applications
Isolated A/B Feed Loss /Open Fuse Alarm
High efficiency : 98%
.
.
.
ATCA Front Board / Blade
Central Office Telecom equipment
-40 to 85ºC ambient temperature operation
High availability server and storage applications
Industry Standard Quarter brick size: 58.4 mm x 36.8 mm x
13.7 mm (2.3 in x 1.45 in x 0.54 in)
.
.
.
.
MTBF : 2,308,563 hours per TELCORDIA
ISO** 9001 & ISO 14001 certified manufacturing facilities
Compliant to RoHS II EU “Directive 2011/65/EU”
Options
.
Choice of short pin lengths
I2C Digital Interface
UL* 60950-1, 2nd Ed. Recognized, CSA† C22.2 No. 60950 1-07
Certified, and VDE‡ (EN60950-1, 2nd Ed.) Licensed
.
.
Meets the voltage and current requirements for ETSI 300-
132-2 and complies with and licensed for Basic insulation
rating per EN60950-1
.
.
2250 Vdc Isolation tested in compliance with IEEE 802.3¤ PoE
standards
ISO**9001 and ISO 14001 certified manufacturing facilities
Description
The PIM400 series of Power Input Modules are designed to greatly simplify the task of implementing dual redundant, hot swap –
48Vdc power distribution with EMI filtering on an ATCA or other telecom boards. The PIM400 with optional I2C digital interface
capability, when used with a variety of GE’s series of Bus converters (BarracudaTM Series) /POLs (DLynxTM Series) provides for a
quick, simple and elegant power solution to a wide variety of demanding & intelligent power system architectures.
*
UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
†
‡
** ISO is a registered trademark of the International Organization of Standards
¤ IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated.
June 20, 2013
©2013 General Electric Company. All rights reserved.