PI49FCT3807
3.3V Fast CMOS Clock Driver
Maximum Ratings
(Above which the useful life may be impaired. For user guidelines, not tested.)
Note:
Storage Temperature ............................................................–65°C to +150°C
Ambient Temperature with Power Applied ...........................–40°C to +85°C
Stresses greater than those listed under MAXIMUM
RATINGS may cause permanent damage to the
Supply Voltage to Ground Potential (Inputs & V Only).....–0.5V to +7.0V device. This is a stress rating only and functional operation
CC
of the device at these or any other conditions above those
indicated in the operational sections of this specification is
Supply Voltage to Ground Potential (Outputs & D/O Only) ..–0.5V to +7.0V
DC Input Voltage ....................................................................–0.5V to +7.0V
DC Output Current............................................................................... 120mA
Power Dissipation................................................................................... 0.5W
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect reliability.
DC Electrical Characteristics (T = –40°C to +85°C V = 3.3V ±0.3V)
A
CC
(1)
Symbol
Parameters
Test Conditions
Min.
Typ.
Max.
Units
V
V
= Min.,
I
I
= -0.1mA
= -8mA
V
2.4
-0.2
-
3.0
CC
IN
OH
OH
CC
V
Output High Voltage
OH
OL
(3)
= V or V
IL
IH
I
I
I
= 0.1mA
= 16mA
= 24mA
-
0.2
0.3
0.2
0.4
0.5
OH
OH
OH
V
V
= Min.,
CC
IN
V
V
Output Low Voltage
= V or V
IL
IH
V
V
Input High Voltage
Input Low Voltage
Input High Current
Input Low Current
Clamp Diode Voltage
Guaranteed Logic HIGH Level (Input Pins)
Guaranteed Logic LOW Level (Input Pins)
2.0
5.5
0.8
1
IH
IL
-0.5
I
I
V
V
V
V
V
V
= Max.
= Max.
V
V
= V
CC
IH
IL
CC
IN
IN
µA
V
= GND
-1
CC
V
= Min., I = -18mA
-0.7
-60
-1.2
-110
200
-240
IK
CC
IN
(4, 5)
I
I
I
Output High Current
= 1.5V, V = V or V , V = 3.3V
-35
50
ODH
ODL
OS
OUT
OUT
IN
IL
IH
CC
(4, 5)
Output Low Current
Short Circuit Current
Input Hysteresis
= 1.5V, V = V or V , V = 3.3V
90
mA
mV
IN
IL
IH
CC
(4, 5)
= Max., V
= GND
-60
-135
150
CC
OUT
VH
Notes:
1. For Max. or Min. conditions, use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 3.3V, +25°C ambient and maximum loading.
3. VOH = VCC – 0.6V at rated current.
4. This parameter is determined by device characterization but is not production tested.
5. Not more than one output should be shorted at one time. Duration of the test should not exceed one second.
PS7010D
09/08/04
2