PG-75
COMPACT PRESSURE GAUGE
■
ENVIRONMENTAL CHARACTERISTICS
Test item
Test conditions
(At 25 5 ꢀC)
Permissible change
Pressure indication, switch operating pressure
and analog output : 5 %F.S. maximum during
test
EMI : EN55011: 2009, A1: 2010 Group 1, class B
EMS : EN61326-1 : 2006 Table 2
EMC
EN61326-2-3 : 2006 Annex BB
■
MULTIPLIER FACTOR
The multiplier factor is selectable by changing the value of third digit on the display during the operation setting.
Pressure Range / Display specification rated pressure
Code/Multiplier Factor
102G
0.0 ~ 100.0
.000 ~ 1.020
0 ~ 1020
0 ~ 750
102R
103G
0 ~ 1000
0.00 ~ 10.20
ー
103R
-100 ~ 1000
-1.02 ~ 10.20
ー
353G
ー
353R
ー
1:×1(kPa)
2:×0.0102
3:×10.2
4:×7.501
5:×0.01
6:× 1 0
7:×0.145
8:×0.001(MPa)
9:×0.2953
-100.0 ~ 100.0
-1.020 ~ 1.020
-1020 ~ 1020
-750 ~ 750
-1.000 ~ 1.000
-1000 ~ 1000
-14.5 ~ 14.5
ー
0.0 ~ 35.7
ー
-1.0 ~ 35.7
ー
ー
ー
ー
ー
.000 ~ 1.000
0 ~ 1000
0.0 ~ 14.5
ー
0.00 ~ 10.00
ー
0.0 ~ 145.0
.000 ~ 1.000
0 ~ 295
-1.00 ~ 10.00
ー
-14.5 ~ 145.0
-.100 ~ 1.000
-30 ~ 295
0.0 ~ 35.0
ー
0 ~ 508
0.00 ~ 3.50
0 ~ 1033
-1.0 ~ 35.0
ー
-15 ~ 508
-0.10 ~ 3.50
-30 ~ 1033
0.0 ~ 29.5
-29.5 ~ 29.5
・
・
・
The settings indicated by "-" on the table above are not selectable because of resolution.
Either "1" for 102A, 102V, 102G, and 102R) or "8" (for 103G, 103R, 353G and 353R) are set prior to delivery.
Changes of the multiplier factor apply to display values. Also, note the changes reset switch setting value and hysteresis.
(
■
SWITCH OUTPUT MODE
SW output is selectable by changing the value of first digit on the display.
<Switch Operation Mode>
Separate mode Window comparator mode
<SW Operation Code>
Output
Mode
SW1
SW2
(HI operation)
(A operation)
Separate
Window comparator
Separate
Window comparator
ON
ON
ON
P2/SW2
OFF
Operation
HI
LO
A
B
HI
LO
A
B
OFF
-Pr
P1/SW1, P2/SW2
P3/SW1, P4/SW2
P1/SW1
Pr
-Pr
Pr
1
2
3
4
5
6
7
8
H
H
H
H
(L operation)
(B operation)
ON
ON
OFF
OFF
OFF
Pr
P1/SW1, P2/SW2
P3/SW1, P4/SW2
P1/SW1
H
P2/SW2
H
-Pr
-Pr
Pr
H
H
P1≦P2 or P1≧P2
P1≦P3–2H and P2≦P4–2H
H:Hysteresis、
P1=Set 1、P2=Set 2
P3=Set 3、P4=Set 4
(Minimum)Set 1
(Maximum)Set 4
(Minimum)Set 1
(Maximum)Set 3
Pressure setting
(Operating point)
Set 1
Set 2
・In the Separate mode, SW 1 corresponds to Setting 1 and SW2 corresponds to Setting 2.
・In the Window Comparator Mode, SW 1 corresponds to the Setting 1(lower limit)and Setting 3(upper limit). Also. SW2 corresonds to the setting 2
(lower limit)and setting 4(upper limit).
・The Hysteresis(H)setting is common to SW 1 and SW 2 operations.
・When SW operation is changed between the Separate Mode and Window Comparator Mode, SW pressure settings that are set separately will be reset.