SPECIFICATIONS
ELECTRICAL
Typical at +25°C, and nominal power supply voltages ±5V, unless otherwise noted.
PCM56U, PCM56P-J, -K
TYP
PARAMETER
MIN
MAX
UNITS
DIGITAL INPUT
Resolution
Digital Inputs(1): VIH
VIL
16
Bits
V
V
µA
µA
MHz
+2.4
0
+VL
+0.8
+1.0
–50
I
IH, VIN = +2.7V
IIL, VIN = +0.4V
Input Clock Frequency
10.0
TRANSFER CHARACTERISTICS
ACCURACY
Gain Error
Bipolar Zero Error
±2.0
±30
%
mV
Differential Linearity Error
Noise (rms, 20Hz to 20kHz) at Bipolar Zero (VOUT models)
±0.001
6
% of FSR(2)
µV
TOTAL HARMONIC DISTORTION
VO = ±FS at f = 991Hz: PCM56P-K
PCM56P-J
–94
–94
–94
–94
–75
–75
–75
–75
–35
–35
–35
–35
–92
–88
–82
–80
–74
–68
–68
–60
–34
–28
–28
–20
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
PCM56P, PCM56U
PCM56P-L
VO = –20dB at f = 991Hz: PCM56P-K
PCM56P-J
PCM56P, PCM56U
PCM56P-L
O = –60dB at f = 991Hz: PCM56P-K
PCM56P-J
V
PCM56P, PCM56U
PCM56P-L
MONOTONICITY
15
Bits
DRIFT (0°C to +70°C)
Total Drift(3)
Bipolar Zero Drift
±25
±4
ppm of FSR/°C
ppm of FSR/°C
SETTLING TIME (to ±0.006% of FSR)
Voltage Output: 6V Step
1.5
1.0
10
350
350
µs
µs
V/µs
ns
1LSB
Slew Rate
Current Output, 1mA Step: 10Ω to 100Ω Load
1kΩ Load(4)
ns
WARM-UP TIME
1
Min
OUTPUT
Voltage Output Configuration: Bipolar Range
Output Current
±3.0
V
mA
Ω
±2.0
Output Impedance
0.10
Short Circuit Duration
Current Output Configuration:
Bipolar Range (±30%)
Output Impedance (±30%)
Indefinite to Common
±1.0
1.2
mA
kΩ
POWER SUPPLY REQUIREMENTS(5)
Voltage: +VS and +VL
–VS and –VL
Supply Drain (No Load): +V (+VS and +VL = +5V)
–V (–VS and –VL = –5V)
+V (+VS and +VL = +12V)
–V (–VS and –VL = –12V)
Power Dissipation: VS and VL = ±5V
+4.75
–4.75
+5.00
–5.00
+10.00
–25.0
+12.0
–27.0
175
+13.2
–13.2
+17.0
–35.0
V
V
mA
mA
mA
mA
mW
mW
260
V
S and VL = ±12V
468
TEMPERATURE RANGE
Specification
Operation
0
–25
–60
+70
+70
+100
°C
°C
°C
Storage
NOTES: (1) Logic input levels are TTL/CMOS-compatible. (2) FSR means full-scale range and is equivalent to 6V (±3V) for PCM56 in the VOUT mode. (3) This is the
combined drift error due to gain, offset, and linearity over temperature. (4) Measured with an active clamp to provide a low impedance for approximately 200ns. (5) All
specifications assume +VS connected to +VL and –VS connected to –VL. If supplies are connected separately, –VL must not be more negative than –VS supply voltage
to assure proper operation. No similar restriction applies to the value of +VL with respect to +VS.
®
2
PCM56