PBMPLS Series
D C / A C S I N E W A V E I N V E R T E R
FEATURES
• 500W - 7000W
• True Sinewave Output
• Massive Overload Capability
• High Efficiency Toroidal Transformer
• CCT Breaker/ Batt Isolator Switch
• Chassis and Wall mounting
SPECIFICATIONS
INPUT
ALARMS & INDICATORS
When inverter is switched on all 3 LEDS light up for one
second for system check procedure
12V, 24V, 48V (Standard)
Input Voltage
Inverter Operation
36V, 72V, 96V, 120V (Also available)
Green LED. Flashes when in standby mode (no load
connected). When load applied LED illuminates
continuously
Voltage range
-20% to +45% of nominal..
Power Indicator
OUTPUT
230Vac 4% (Standard)
110Vac 4% (Option)
Red LED. In order to protect the battery the inverter will
shutdown after 5 secs if the battery voltage falls below
its limit (Undervolts) LED remains continous or exceeds
the maximum (Overvolts) LED will continue to flash.
Output Voltage
Undervolts/Overvolts
Output Frequency
Output Waveform
Power factor correction
Crest factor
50/60Hz 0.1
True sinewave < 4% THD.
All conditions.
>4
Red LED, If the internal temperature exceeds safe
operating limits for more than 5 secnds, the inverter will
shut down in Over temp with this LED on continuously.
Allow 5mins for the inverter to cool and reset the unit.
Over temperature
Over load
Load start sensitivity
Efficiency
0-20W
Red LED, if the load demands more current than the
inverter can safely supply for more than 5 seconds, the
inverter will shutdown in Overload and this LED will flash
94%Typically
PROTECTION
OPTIONAL FEATURES
DC to AC isolation
Over-load protection
Over-temperature protection
Short circuit protection
3500V
Yes.
CODE
ADD OPTION TO THE END OF INVERTER PART NUMBER
RCD fitted in place of hardware junction box of AC output.
MIL spec conformal coating applied to final assembly.
Ruggedisation for high vibration environment.
D
G
R
K
Yes.
Yes.
Battery under and
over voltage protection
Yes.
Automatic transfer switch 25Amp for 1000W to 1800W.
The circuit breaker by pushing switch "UP"
the battery supply is connected to the
inverter. The circuit breaker will turn OFF
automatically if too large a load is left on
the inverter continuously. Reset the switch
after allowing approx 5mins to cool. If the
inverter shuts down due to overload,
undervolts or overvolts it can be reset by
turning the circuit breaker OFF, waiting 10
seconds (or until LED goes out). Then
turning it on again.
Automatic transfer switch with ON delay
timer and voltage sensing module. 40Amps
for 2000W to 4000W and 65Amp for
5000W to 7000W models.
KX
V
H
L
AC output voltage e.g. 100-120Vac.
Frequency 60Hz
Circuit breaker On/Off
"AC OK" alarm relay contact
Twin switched GPO
(available only on 1000W to 5000W models).
C
Twin switched RCD GPO
(available only on 1000W to 5000W models).
ENVIRONMENT
Temperature range
Cooling
D
-10°C to 50°C
MECHANICAL
Thermostatically controlled 2-speed fan.
Single power outlet (500-600W models).
Single power outlet & screw terminal junction box
(1000-1800W models).
STANDARDS & APPROVALS
Safety standards
C-tick
AC outlet
AS3100, AS3000
Screw terminal junction box (2000-7000W models).
AS/NZS CISPR14, AS/NZS 1044
AS2279, EN55014
Heavy duty low loss battery leads
Red battery positive, Black battery negative
Battery leads
Dimensions
EMC standards
500-600W: 260x160x100mm
1kw-1.8kw: 330x296x150mm
2kw-3.5kw: 370x386x180mm
4kw-7kw: 475x458x187mm
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
Doc. No. PBMPLS Rev.E 20-01-16