Model - PBMN industrial Low Pressure
Technical specification
Electrical specification
Measuring principle
Measuring ranges
Type of pressure
Pꢄezoꢂeꢇꢄꢇtꢄve ꢇꢄlꢄcoꢅ ꢇeꢅꢇoꢂ
1 … 0 baꢂ ꢃp to 0 … 40 baꢂ
Output signal / Power Supply 4 … 20 ꢆꢁ / 8 … 30 VDC
0…10 V / 13 … 30 VDC
-
Load impedance
relatꢄve / ꢁbꢇolꢃte
Current ouput
Voltage output
rΩ = (uꢇꢃpply-8 V) / 20 ꢆꢁ
> 5 KΩ
Accuracy (20 °C)
(lꢄꢅeaꢂꢄty, hyꢇteꢂeꢇꢄꢇ, ꢂepeatabꢄlꢄty)
0.5% Fs, 0.25% Fs, 0.1% Fs
Insulation resistance
Electrical connections
>100 MΩ at 750 VDC
Zero thermal drift
≤ ± 0.03% FS/10 K
≤ ± 0.03% FS/10 K
0.1 % Fs
see page 4
Span thermal drift
Annual stability
Material
Response time (10 … 90%)
Process connections
≤ 5 ms
Process connection
and housing
ss 1.4404 ꢁisi 316L
see page 4
Diaphragm
Sealing
Cable
ss 1.4435 ꢁisi 316L
nBr oꢂ FKm (Vꢄtoꢅ®)
Pur
Environment
Temperature
Storage
-40 … +85 °C
-40 … +120 °C
-40 … +85 °C
Medium
Ambient
Approvals
CE conformity
ꢀmC dꢄꢂectꢄve 2004/108/Cꢀ
ꢄꢅ accoꢂdaꢅce wꢄth ꢀn61000-6-2,
ꢀn 61000-6-3, Pꢂeꢇꢇꢃꢂe dꢄꢂectꢄve
97/23/Cꢀ
Protection rating
iP65 (ꢀn 60529) ꢃp to iP67
depeꢅdꢄꢅg oꢅ electꢂꢄcal coꢅꢅectꢄoꢅ
Vibration IEC60068-2-6
1.5 ꢆꢆ p-p (10 – 57 Hz),
10 g (58 Hz – 2 KHz)
10 cycleꢇ wꢄthꢄꢅ 2.5 h peꢂ axꢄꢇ
ATEX
Shock IEC60068-2-27
Bump IEC60068-2-29
Random IEC60068-2-64
50 g/11 ꢆꢇ 100 g/6 ꢆꢇ
10 x iꢆp. peꢂ ꢁxꢄꢇ aꢅd dꢄꢂectꢄoꢅ
ATEX II 1G
Ex ia IIC T4/T6 Ga
ꢁll veꢂꢇꢄoꢅꢇ wꢄthoꢃt Din coꢅꢅectoꢂ
aꢅd wꢄth oꢃtpꢃt ꢇꢄgꢅal code ꢁ1
100 g/2 ꢆꢇ
4000 x iꢆp. peꢂ ꢁxꢄꢇ aꢅd dꢄꢂectꢄoꢅ
0.1 g2/Hz (20 Hz – 1 KHz)
30 ꢆꢄꢅ peꢂ axꢄꢇ (>10 g rms)
ATEX II 1/2G
Ex ia IIC T4/T6 Ga/Gb
ꢁll veꢂꢇꢄoꢅꢇ wꢄth Din coꢅꢅectoꢂ
aꢅd oꢃtpꢃt ꢇꢄgꢅal code ꢁ1
ATEX II 1D
Ex ia IIIC T107°C IP6X Da
ꢁll veꢂꢇꢄoꢅꢇ wꢄth oꢃtpꢃt ꢇꢄgꢅal
code ꢁ1
Barrier data
Ui ≤ 30 V
Ii ≤ 100 mA
Pi ≤ 750 mW
Capacity
Ci ≤ 17 nF
CCable ≤ 0.12 nF/m
Inductivity
Li ≤ 3 μH
LCable ≤ 1.1 μH/m
Temperature class
(aꢆbꢄeꢅt teꢆpeꢂatꢃꢂe)
T1 ... T4: -40 <Taꢆb < 85 °C
T1 ... T6: -40 <Taꢆb < 70 °C
Temperature class
(ꢆedꢄꢃꢆ teꢆpeꢂatꢃꢂe)
T1 ... T4: -40 <Tꢆed < 115 °C
T1 ... T6: -40 <Tꢆed < 75 °C
Foꢂ the applꢄcatꢄoꢅ ꢄꢅ ꢀx zoꢅe yoꢃ have to ꢂeꢇpect the coꢅdꢄtꢄoꢅꢇ
mentioned in the ATEX Type Examination Certificate (SEV 11 ATEX
0129).
You find the certificates and manuals under http://www.baumer.com/
Measuring Ranges
Pressure in bar
Pressure
range
-0.1 … +0.1
0 … 0.1
0 … 0.16
0 … 0.25
-0.2 … +0.2
0 … 0.4
0 … 0.6
0 … 1
-1 … 0
-1 … 0.6
0 … 1.6
0 … 6
0 … 10
-1 … 9
0 … 16
-1 … 15
0 … 20
0 … 25
-1 … 24
0 … 40
-1 … 39
0 … 2
0 … 2.5
-1 … 1.5
0 … 4
0 … 5
-1 … 3
-1 … 5
Overpressure
Burst pressure
1
2
3
6
3
6
15
30
60
70
135
270
120
140
www.baumer.com
Design and specifications subject to change without notice
Data sheet A11.37
Page 3