描述
AC-DC Power Supplies

PBM200PS12-C 数据手册

 浏览型号PBM200PS12-C的Datasheet PDF文件第2页 
200 Watts  
xppower.com  
PBM200 Series  
Worldwide Medical Approvals  
Single, Dual, Triple and Quad Outputs  
Small Size - Only 7” x 4” x 1.5”  
Power Fail Detect & Remote On/Off  
Universal AC Input with Active PFC  
High Reliability - 350k Hours MTBF  
100 Watt Convection-Cooled Rating  
Specification  
Input  
General  
Input Voltage  
Input Frequency  
Input Current  
• 90-264 VAC  
• 47-63 Hz  
Efficiency  
Isolation  
• Up to 80%  
• 4000 VAC Input to Output  
1500 VAC Input to Ground  
500 VAC Output to Ground  
• 3.2 A rms at 115 VAC,  
1.6 A rms at 230 VAC  
Switching Frequency  
Power Density  
• 100 kHz 12 kHz  
• 4.76 W/In3  
Inrush Current  
Power Factor  
• 20 A at 115 VAC, 40 A at 230 VAC  
cold start 25 ºC  
• 0.98 typical  
Power Fail Detect  
AC OK = TTL logic high  
AC not OK = TTL logic low  
Earth Leakage Current • 90 µA max at 115 VAC, 60 Hz  
150 µA max at 230 VAC, 50 Hz  
MTBF  
• 350 kHrs per MIL-HDBK-217F at +25 ˚C  
Input Protection  
• Both line and neutral fused  
Environmental  
Output  
Operating Temperature • 0 ˚C to +70 ˚C, derate linearly from 100%  
power at +50 ˚C to 50% power at +70 ˚C  
Output Voltage  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
Start Up Delay  
Start Up Rise Time  
Hold Up Time  
• See table  
Cooling  
• ‘C’ versions have internal fan,  
‘B’ versions are derated with convection  
cooling or require 25 CFM (see note 4)  
• Not user-adjustable  
2%  
• See table & note 5  
• 2 s max  
Operating Humidity  
Storage Temperature  
Operating Altitude  
Shock  
• Up to 95% RH, non-condensing  
• -40 ˚C to +85 ˚C  
• 18 ms typical  
• 2500 m  
• 20 ms minimum at full load & 110 VAC  
• Half sine pulse. acceleration 50 g, 11 ms  
duration, 3 shocks in each direction,  
unpackaged, non-operating  
Drift  
0.2%  
Line Regulation  
Load Regulation  
Transient Response  
0.5% max  
• See note 7  
Vibration  
• Sinusoidal 10-55 Hz, amplitude 0.15 mm,  
30 min/axis, unpackaged, non-operating  
• 4% max deviation, recovery to within  
1% in 500 µs for a 25% load change  
EMC & Safety  
Ripple & Noise  
• 2% max pk-pk, 20 MHz BW with a 22 µF  
electrolytic & a 0.47 µF tantalum capacitor  
Emissions  
• EN55011 & FCC Class B conducted  
& radiated  
Overvoltage Protection • 112-140% Vnom output 1 only, recycle  
input to reset  
Harmonic Currents  
Voltage Flicker  
ESD Immunity  
Radiated Immunity  
EFT/Burst  
• EN61000-3-2  
Overtemperature  
Protection  
• Shutdown at +85 ºC (singles) or +105 ºC  
(multi outputs) with auto recovery,  
measured internally  
• EN61000-3-3  
• EN61000-4-2, level 3 Perf Criteria A  
• EN61000-4-3, level 3 Perf Criteria A  
• EN61000-4-4, level 3 Perf Criteria A  
• EN61000-4-5, level 3 Perf Criteria A  
• EN61000-4-6 3 V, Perf Criteria A  
Overload Protection  
• 140-200% typical, auto recovery  
Short Circuit Protection Trip and restart (Hiccup mode)  
Surge  
Temperature  
Coefficient  
• 0.04%/˚C  
Conducted Immunity  
Dips & Interruptions  
• EN61000-4-11, 30% 10 ms,  
60% 100 ms, >95% 5000 ms,  
Perf Criteria A, B, B  
Remote Sense  
• Single output models only.  
Compensates for up to 0.5 V drop  
Remote On/Off  
• On = Logic low or open circuit  
Off = Logic high  
Safety Approvals  
• EN60601-1, UL60601-1,  
CSA22.2 No. 601-1 per cUL, CE Mark  

与PBM200PS12-C相关器件

型号 品牌 描述 获取价格 数据表
PBM200PS15-C XPPOWER AC-DC Power Supplies

获取价格

PBM200PS24-C XPPOWER AC-DC Power Supplies

获取价格

PBM200PS30-C XPPOWER AC-DC Power Supplies

获取价格

PBM200PS3V3-C XPPOWER AC-DC Power Supplies

获取价格

PBM200PS48-C XPPOWER AC-DC Power Supplies

获取价格

PBM200PT01-C XPPOWER AC-DC Power Supplies

获取价格