PBLN Series
6 0 - 2 4 0 W AT T S - A C / D C L I N E A R S I N G L E O U T P U T
FEATURES
•
•
•
•
•
Very low RF noise
Highly efficient linear
Chassis mounting
Rack mounting
Superior line & load regulation
SPECIFICATIONS
INPUT
Operating temperature
Derating
0°C to 50°C at full load
Voltage
240VAC 5% full output current.
Other voltages on request
50°C to 70°C derate linearly to 40%
Natural convection.
Cooling
Frequency
Input protection
Efficiency
50Hz–60Hz
STANDARDS
Safety
Yes, internal fuse
Meets AS/NZS 60950, Class 1
AS/NZS CISPR11 Group 1 Class A.
AS/NZS 3548:1995 Class B
60%–80% depending on output voltage
C-Tick
Isolation
Input – Output: 3500VAC, 1 min
Input – Ground: 1500VAC (with varisters
removed)
EMC compliances
MECHANICALS
Connections
Mounting
Output – Ground: 500VAC, 1 min
7 way 9.5mm barrier terminal block
OUTPUT
CM: Chassis mount
RM: Rack mount
Output voltage
Output current
Output ripple
See table
See table
0.5mV pk-pk max. (100Hz–120Hz).
0.1% max.
Line regulation
Load regulation
Temperature coefficient
SELECTION TABLE
0.3% max.
MODEL
NUMBER
RIPPLE
50ppm per °C typical
( 250ppm per °C max.).
OUTPUT
NOISE
POWER
PBLN1205CM
PBLN1210CM
PBLN2405CM
PBLN2410CM
PBLN4805CM
PBLN1205RM
PBLN1210RM
PBLN2405RM
PBLN2410RM
PBLN4805RM
12V
12V
24V
24V
48V
12V
12V
24V
24V
48V
5A
10A
5A
0.5mVp-p
0.5mVp-p
0.5mVp-p
0.5mVp-p
0.5mVp-p
0.5mVp-p
0.5mVp-p
0.5mVp-p
0.5mVp-p
0.5mVp-p
60W
120W
120W
240W
240W
60W
Overvoltage protection
SCR crowbar, factory set at 120% V
out 5%.
Overcurrent protection
High temperature
Alarms
Foldback current limiting 115% I max.
Thermal shutdown, Auto electronic reset.
10A
5A
Optional DC OK alarm with relay output, add
suffix “-AL”.
5A
10A
5A
120W
120W
240W
240W
10A
5A
Doc. No. PBC9 Rev.C 28-4-11
Powering Progress – www.powerbox.com.au
83