6.1.3 Adjust R08 such that the meter reads ~ 200 . This value added to the fixed resistor  
R07 should total ~ 2.3 k. Note: R07 is 1.7 kon the boards with the  
MIL-COTS PRM.  
6.1.4 One could also probe between SG and the ON side of switch OSV (#5) and set the  
total resistance shown to ~ 2.3 k.  
6.1.5 Move switch OSF (#6) to the OFF position.  
6.1.6 Move switch OSV (#5) to the ON position.  
6.1.7 The unit is now ready to provide the desired output voltage set point.  
6.1.8 Powering the device on should yield a no-load output voltage of the nominal specified  
value.  
6.1.9 The output voltage can now be set to the desired value by varying trim pot OS (R08).  
6.1.10 IT MAY BE POSSIBLE TO INADVERTENTLY TRIM THE OUTPUT TOO HIGH ENABLING  
THE OVERVOLTAGE PROTECTION CIRCUIT. If this happens, reduce the impedance of  
R08. The initial conditions of steps 6.1.2 and 6.1.3 can be used to recover.  
6.1.11 The desired output voltage set point can also be achieved by using the equations in  
the data sheet and setting the total OS resistance (R07+R08) to that value and then  
configuring the switches as above.  
6.1.12 Be certain to adhere to the power vs. output voltage curve in the data sheet to avoid  
over powering the device!  
6.2 Adjusting the Current Limit  
6.2.1 Increasing the load beyond the rated maximum may activate the PRMs internal  
current limit (see data sheet for values) feature. Certain applications may require a  
lower limit and for those situations we offer the adjustment feature.  
6.2.2 Refer to the data sheet for the resistance vs. limit curve for the desired limit value.  
Note: the IL values of resistors installed on this board (R01+R02: 2 k+100 k) may  
not cover the entire range of the curve.  
6.2.3 The adjustable IL mode is engaged by repositioning the IL switch (#2) from OFF to ON.  
(This may be done while the unit is powered.)  
6.2.4 Adjusting the IL trim pot will reduce the current limit from the factory preset limits  
specified in the data sheet. It is not possible to increase this limit beyond the factory  
settings.  
6.2.5 To reinstate the factory limit return the IL switch to the OFF position.  
6.3 Trimming the output voltage using SC  
6.3.1 Once the output voltage has been determined and set using the OS resistors, it is still  
possible to trim the output down to 26 V using the SC control. Adjusting the output  
in this manner rather than merely adjusting the output via the OS values provides  
improved regulation.  
6.3.2 Depending upon the chosen initial output voltage determined by the OS resistors, the  
amount of available adjustment might be very limited. Enabling SC adjustment by  
toggling the SC switch (#3) to the ON position may result in shut down.  
6.3.3 To avoid the situation described in 6.3.2, set the SC trim pot R04 (100 k) to its  
maximum value prior to enabling the switch.  
6.3.4 The data sheet has an equation for calculating the appropriate resistor value for a  
trimmed output voltage. This value would be the sum of fixed resistor R03 (5.11 k)  
and the trim pot R04. R04 can be set using the test points provided locally, or the  
sum set using the SC and SG test points (Items 3 and 6) when the SC switch is ON.  
6.4  
Activating Adaptive Loop Regulation and Interconnect Compensation CD.  
6.4.1 The CD switch (#4) and the associated fixed resistor R05 (20 ) and trim pot R06  
(20 ) enable the PRM Adaptive Loop regulation feature, which compensates for  
the VTM output resistance induced voltage drop as the load current from the VTM is  
increased.  
6.4.2 This feature is intended to be used with mating VTM-CB discussed in detail in the  
next section.  
UG:003  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 6  

与P036F048T12AL-CB相关器件

型号 品牌 描述 获取价格 数据表
P036PH02CK IXYS Silicon Controlled Rectifier, 100 A, 200 V, SCR

获取价格

P036PH02CKO IXYS Silicon Controlled Rectifier, 100 A, 200 V, SCR

获取价格

P036PH02CL IXYS Silicon Controlled Rectifier, 100A I(T)RMS, 200V V(DRM), 200V V(RRM), 1 Element

获取价格

P036PH02CLO IXYS Silicon Controlled Rectifier, 100A I(T)RMS, 200V V(DRM), 200V V(RRM), 1 Element

获取价格

P036PH02CM IXYS Silicon Controlled Rectifier, 100A I(T)RMS, 200V V(DRM), 200V V(RRM), 1 Element

获取价格

P036PH02CMO IXYS Silicon Controlled Rectifier, 100A I(T)RMS, 200V V(DRM), 200V V(RRM), 1 Element

获取价格