2.0 Hook Up  
2.1  
Connect the power supply +Out lead to the +In terminal of the Customer  
Evaluation Board.  
2.2  
Connect the power supply –Out lead to the –In terminal of the Customer  
Evaluation Board.  
2.3  
2.4  
A high quality, low-noise power supply should be connected to these locations  
Connect a lead between the +Out of the Customer Evaluation Board and +In  
of the load.  
2.5  
2.6  
Connect a lead between the –Out of the Customer Evaluation Board and –In  
of the load.  
Connections to these locations should be with short heavy gauge leads.  
3.0 Verify Connections  
4.0 Test Sequence  
4.1  
4.2  
4.3  
4.4  
4.5  
Have the latest version of the PRM® data sheet in hand.  
Assure that the DC supply is set to 0 Vdc prior to turning the unit on.  
Confirm that the switch bank is configured as shown in the silk screen on the board.  
Turn on the DC supply.  
Make sure the DC load is set to constant current and at 0 A prior to turning  
on the load.  
4.6  
4.7  
Turn on the DC load.  
Connect an oscilloscope to the test point provided to monitor output voltage. Many  
types of scope probes may be directly connected to these points if the probe is  
equipped with a removable plastic sheath. Be careful to avoid creating ground loops  
when making measurements of this voltage and the input voltage. It is recommended  
that the measurements be made separately. Shorting the -input and -output of the PRM  
will defeat the PRM current limit feature as the current shunt is in this path.  
Turn on a fan if desired.  
4.8  
4.9  
4.10  
Raise the DC input voltage to the nominal value indicated on the data sheet.  
Verify no load operation by raising and lowering the input voltage through the entire  
input voltage range. The output voltage should remain constant within the tolerance  
indicated in the data sheet.  
4.11  
4.12  
Re-establish the nominal input voltage.  
Slowly increase the load current to full load while monitoring the output voltage. The  
output voltage should remain within the limits specified in the appropriate PRM data  
sheet.  
4.13  
4.14  
Return the load current to 0 A and decrease the input voltage to low line.  
Repeat step 4.12. Depending upon the supply used and the source impedance it may  
be necessary to adjust the input voltage to keep the input to the PRM at low line.  
Return the load current to 0 A and increase the input voltage to high line.  
Repeat step 4.12.  
4.15  
4.16  
5.0 You have now verified the functionality of the PRM over the entire line and load  
operating range.  
6.0 Deviating from Nominal Settings  
This board has provisions, as described in the Board Overview section, to adjust the  
configuration of the PRM about the nominal values. The data sheet for the PRM has equations  
and curves for determining the required resistor values needed for specific conditions.  
Applications requiring output voltages other than the nominal setting will need to have the  
new value set via the trim pots and respective switches. Reference Items 4 and 5 of the Board  
Overview and the schematic shown in Figure 2.  
6.1  
Adjust the PRM Output Voltage Set Point  
6.1.1 Make sure that the power is removed from the unit prior to making adjustment.  
6.1.2 Using a DMM (set to measure resistance), probe between SG (Item 3) and the pad  
labeled OS located next to the 5 ktrim pot R08.  
UG:003  
vicorpower.com  
Applications Engineering: 800 927.9474  
Page 5  

与P036F048T12AL-CB相关器件

型号 品牌 描述 获取价格 数据表
P036PH02CK IXYS Silicon Controlled Rectifier, 100 A, 200 V, SCR

获取价格

P036PH02CKO IXYS Silicon Controlled Rectifier, 100 A, 200 V, SCR

获取价格

P036PH02CL IXYS Silicon Controlled Rectifier, 100A I(T)RMS, 200V V(DRM), 200V V(RRM), 1 Element

获取价格

P036PH02CLO IXYS Silicon Controlled Rectifier, 100A I(T)RMS, 200V V(DRM), 200V V(RRM), 1 Element

获取价格

P036PH02CM IXYS Silicon Controlled Rectifier, 100A I(T)RMS, 200V V(DRM), 200V V(RRM), 1 Element

获取价格

P036PH02CMO IXYS Silicon Controlled Rectifier, 100A I(T)RMS, 200V V(DRM), 200V V(RRM), 1 Element

获取价格