Technical Data Sheet for NL1023T
Single-Stage Thermoelectric Module
NOMINAL PERFORMANCE IN NITROGEN
Hot Side Temperature (°C)
Δ Tmax (°C):
27
64
50
73
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
Device ZT
9.2
1.8
8.0
3.86
0.77
10.5
1.8
9.0
--
--
PRODUCT FEATURES
ORDERING OPTIONS
Model Number
Description
TEM, Top and Base Metallized
Exterior
TEM, Base Metallized Exterior
TEM, No Metallized Exterior
TEM, Top and Base Pre-Tinned with
138 ºC Solder
•
•
•
RoHS EU Compliant
Rated operating temperature of 130°C.
Pre-tinned metallized ceramic surface(s) with 138°C solder,
option available.
NL1023T-01AC
NL1023T-02AC
NL1023T-03AC
NL1023T-04AC
OPERATION CAUTIONS
INSTALLATION
For maximum reliability, storage and operation below
85°C in a non-condensing environment is recommended.
To minimize thermal stress, use linear/proportional
temperature control or a similar method rather than an
ON/OFF method.
Recommended mounting methods: Bonding with thermal
epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEM Installation Guide.
II-VI Marlow – Dallas, TX USA
214-340-4900
877-627-5691
marlow.sales@ii-vi.com
Marlow Industries Europe
GmbH - Germany
+49 (0) 6150 5439 - 403
info@marlow-europe.eu
II-VI Japan Inc.
81 43 297 2693 (tel)
center@ii-vi.co.jp
www.ii-vi.co.jp
II-VI Singapore Pte., Ltd.
(65) 6481 8215 (tel)
info@ii-vi.com.sg
Marlow Industries China, II-VI
Technologies Beijing
86-10-643 98226
info@iivibj.com
MI Form 005-0808 Rev. B
DOC # 102-0297 REV J - PAGE 1 OF 3