5秒后页面跳转
NDY1212C PDF预览

NDY1212C

更新时间: 2024-02-11 05:59:17
品牌 Logo 应用领域
村田 - MURATA 转换器电源电路
页数 文件大小 规格书
4页 192K
描述
Isolated 3W Wide Input DC/DC Converters

NDY1212C 技术参数

生命周期:Active包装说明:,
Reach Compliance Code:unknown模拟集成电路 - 其他类型:DC-DC REGULATED POWER SUPPLY MODULE
Base Number Matches:1

NDY1212C 数据手册

 浏览型号NDY1212C的Datasheet PDF文件第1页浏览型号NDY1212C的Datasheet PDF文件第3页浏览型号NDY1212C的Datasheet PDF文件第4页 
NDY Series  
Isolated 3W Wide Input DC/DC Converters  
OUTPUT CHARACTERISTICS  
Parameter  
Voltage set point accuracy  
Conditions  
With external input/output capacitors  
Min.  
Typ.  
1
Max.  
5
Units  
%
Low line to high line, 3.3V output with external input/output capacitors  
Low line to high line, all other outputs with external input/output capacitors  
25% load to 100% load, 3.3V output with external input/output capacitors  
25% load to 100% load, all other outputs with external input/output capacitors  
BW = 20Hz to 300kHz, 3.3V output with external input/output capacitors  
BW = 20Hz to 300kHz, all other outputs with external input/output capacitors  
BW = DC to 100MHz, 3.3V output with external input/output capacitors  
BW = DC to 20MHz, all other outputs with external input/output capacitors  
0.05  
0.05  
0.6  
0.2  
80  
0.25  
0.5  
1.0  
0.5  
120  
10  
%
Line regulation  
Load regulation  
Ripple1  
%
%
%
mV rms  
mV p-p  
5
180  
100  
Noise1  
50  
GENERAL CHARACTERISTICS  
Parameter  
Conditions  
Min.  
160  
290  
80  
Typ.  
Max.  
220  
560  
220  
560  
Units  
kHz  
100% load VIN nominal 3.3V output  
25% load VIN nominal 3.3V output  
100% load VIN nominal, all other outputs  
25% load VIN nominal, all other outputs  
Switching frequency  
290  
TEMPERATURE CHARACTERISTICS  
Parameter  
Operation  
Storage  
Conditions  
Ambient temperature  
Min.  
-40  
-50  
Typ.  
Typ.  
Max.  
85  
130  
Units  
ºC  
Cooling  
Free air convection  
ISOLATION CHARACTERISTICS  
Parameter  
Isolation test voltage  
Resistance  
Conditions  
Flash tested for 1 second  
Viso=500VDC  
Min.  
1000  
1
Max.  
Units  
VDC  
GΩ  
TECHNICAL NOTES  
ISOLATION VOLTAGE  
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,  
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.  
Murata Power Solutions NDY series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.  
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”  
The NDY series has been recognized by Underwriters Laboratory for functional isolation. Both input and output should normally be maintained within SELV limits i.e. less than 42.4V  
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.  
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier  
must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according  
to safety standard requirements.  
REPEATED HIGH-VOLTAGE ISOLATION TESTING  
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,  
construction and environment. The NDY series has an EI ferrite core, with no additional insulation between primary and secondary windings of enameled wire. While parts can be  
expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane)  
is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly  
advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.  
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further  
insulation system of physical spacing or barriers.  
SAFETY APPROVAL  
The NDY series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation for a maximum case temperature limit of 130ºC (case temperature  
measured on the face opposite the pins). File number E179522 applies.  
Note: This series gained UL 60950 recognition for products manufactured on or after datecode G1123, any NDY parts manufactured before this date code should not be considered  
UL 60950 recognized. Any NDY that is UL recognized will be printed with the UL logo.  
1. For lower ripple refer to circuit for reduced ripple.  
www.murata-ps.com/support  
KDC_NDY.F02 Page 2 of 4  

与NDY1212C相关器件

型号 品牌 描述 获取价格 数据表
NDY1215 CANDD Isolated 3W Wide Input DC-DC Converters

获取价格

NDY1215C MURATA Isolated 3W Wide Input DC/DC Converters

获取价格

NDY2403 CANDD Isolated 3W Wide Input DC-DC Converters

获取价格

NDY2403C MURATA Isolated 3W Wide Input DC/DC Converters

获取价格

NDY2405 CANDD Isolated 3W Wide Input DC-DC Converters

获取价格

NDY2405 MURATA DC-DC Regulated Power Supply Module, 1 Output, 3W, Hybrid

获取价格