5秒后页面跳转
MY4 DC6 (S) PDF预览

MY4 DC6 (S)

更新时间: 2022-09-29 18:54:11
品牌 Logo 应用领域
欧姆龙 - OMRON 光电二极管
页数 文件大小 规格书
35页 9402K
描述
RELAY GENERAL PURPOSE 4PDT 3A 6V

MY4 DC6 (S) 数据手册

 浏览型号MY4 DC6 (S)的Datasheet PDF文件第27页浏览型号MY4 DC6 (S)的Datasheet PDF文件第28页浏览型号MY4 DC6 (S)的Datasheet PDF文件第29页浏览型号MY4 DC6 (S)的Datasheet PDF文件第31页浏览型号MY4 DC6 (S)的Datasheet PDF文件第32页浏览型号MY4 DC6 (S)的Datasheet PDF文件第33页 
MY  
Engineering Data  
Engineering Data  
MY2K(-02)  
Maximum Switching Capacity  
Endurance Curve  
10  
5
AC resistive load  
500  
500  
AC inductive load  
(cos φ = 0.4)  
110 VAC resistive load  
220 VAC resistive load  
110 VAC inductive load  
(cos φ = 0.4)  
1
100  
50  
100  
50  
0.5  
DC resistive load  
DC inductive load  
(L/R = 7 ms)  
30 VDC resistive load  
220 VAC  
inductive load  
(cos φ = 0.4)  
30 VDC inductive load  
(L/R = 7 ms)  
0.1  
10  
10  
0
0.5  
1
1.5  
5
10  
50  
100  
500  
0
1
2
3
Contact current (A)  
Contact voltage (V)  
Contact current (A)  
MY2K 100 VAC  
Malfunctioning Shock  
MY2K 24 VDC  
Magnetic Interference  
Latching Deterioration Over  
(External Magnetic Field)  
Time  
Y
Not energized  
1000  
(Average values)  
N = 24  
Measurement: The rate of deterioration in latching ability was  
Energized  
Armature deviation  
when set  
N = 5  
measured over time with the Relay left at a normal temperature  
(20 to 30°C) after latching by applying the rated voltage.  
900  
Measurement: The percentage of change in the operating and  
release voltages in a uniform external magnetic field  
were measured (worst magnetic field direction).  
1000  
Z
800  
X
400  
350  
N
S
S
N
100  
90  
80  
70  
60  
700  
400  
400  
80  
60  
Average value  
N = 20  
40  
20  
Measurement: Shock was applied 2  
times each in 6 directions along 3  
axes with the Relay energized and not  
energized to check the shock values  
that cause the Relay to malfunction.  
Criteria: Non-energized: 200 m/s2  
Energized: 200 m/s2  
300  
Set voltage  
40  
60  
80  
400  
40  
60  
80  
20  
40  
60  
80  
Reset voltage  
X’  
Z’  
1000  
1000  
900  
Unit: m/s2  
1000  
Y’  
0
50 100  
300 500 1,000  
5,000 10,000  
Uniform magnetic field strength (0e)  
Elapsed time (h)  
Dimensions  
(Unit: mm)  
Safety Precautions  
• For applications that use a 200 VAC power  
supply, connect external resistors Rs and Rr to  
a 100 VAC Relay.  
Relays with Plug-in Terminals  
or Soldered Terminals  
MY2K  
TerminalArrangement/Internal  
Connections (Bottom View)  
1
5
4
8
For AC  
2.6  
9
10  
11  
12  
14  
Ten, 1.2-dia. × 2.2 oval holes  
0.5  
13  
Rr  
28 max.  
Note: R is a resistor for ampere-  
turn correction. This resistor  
is built-in to 50-VAC and  
higher models.  
Rs  
6.3  
Rs: 7.3 kΩ, 3 W min.  
Rr: 14.3 kΩ, 1 W min.  
Set power supply  
0.5  
21.5 max.  
Reset power supply  
36 max.  
6.4  
(The coil has no polarity.)  
Do not apply a voltage to the set and reset coils at the  
same time. If you apply the rated voltage to both coils  
simultaneously, the Relay will be set.  
Relays with PCB Terminals  
MY2K-02  
PCB Processing Dimensions  
(Bottom View)  
The minimum pulse width in the performance column is  
the value for the following measurement conditions: an  
ambient temperature of 23° C with the rated operating  
voltage applied to the coil. The performance values  
given here may not be satisfied due to use over time  
and a reduction in latching performance due to  
changes in the ambient temperature or in the  
conditions of the application circuit.  
For DC  
Note: The dimensional  
tolerance is 0.1.  
2.6  
1
For actual use, apply the rated operating voltage with a  
pulse width based on the actual load and reset the  
Relay at least once per year to prevent degradation  
over time.  
If the Relay is used in an environment with strong  
magnetic fields, the surrounding magnetic field can  
demagnetize the magnetic body and cause unintended  
operation. Therefore, do not use these Relays in  
environments with strong magnetic fields.  
Note: Pay close attention to the set  
coil and reset coil polarities. If  
the connections are not  
correct, unintendedoperation  
may occur.  
3.5  
Ten, 1.3-dia. holes  
0.5  
28 max.  
6.3  
36 max.  
4
21.5 max.  
Relay Replacement  
To replace the Relay, turn OFF the power supply  
to the load and Relay coil sides to prevent  
unintended operation and possible electrical  
shock.  
Applicable Sockets  
Use only combinations of OMRON Relays and  
Sockets.  
30  

与MY4 DC6 (S)相关器件

型号 品牌 描述 获取价格 数据表
MY400 MICROSEMI Bridge Rectifier Diode, 1 Phase, 25A, 400V V(RRM), Silicon,

获取价格

MY400X MICROSEMI 25AMP FAST RECOVERY FULL WAVE BRIDGE RECTIFIER

获取价格

MY400XS MICROSEMI 暂无描述

获取价格

MY400XT MICROSEMI Bridge Rectifier Diode, 1 Phase, 25A, 400V V(RRM), Silicon, HERMETIC SEALED, GLASS PACAKGE

获取价格

MY4-02100/110VAC OMRON Power/Signal Relay, 4PDT, Momentary, 1100mW (Coil), 3A (Contact), 24VDC (Contact), AC Inpu

获取价格

MY4-02100/110VDC OMRON Power/Signal Relay, 4PDT, Momentary, 0.01A (Coil), 110VDC (Coil), 900mW (Coil), 3A (Contac

获取价格