MXR7999V SPECIFICATIONS (Measurements @ 25C, Acceleration = 0 g unless otherwise noted; VDD = 5.0V
unless otherwise specified)
MXR7999V
Parameter
Conditions
Min
Typ
Max
Units
SENSOR INPUT
Measurement Range1
Non linearity
Each Axis
g
1.7
Best fit straight line
1.0
0.5
0.5
2.0
% of FS
degrees
%
Alignment Error2
Transverse Sensitivity3
SENSITIVITY
Each Axis
Sensitivity, Analog Outputs at pins
Xout and Yout4
Change over Temperature
ZERO g BIAS LEVEL
0 g Offset
0 g Voltage
@5.0V supply
from 25C, –40C to +105C
Each Axis
950
-5
1000
1050
+5
mV/g
%
-0.15
2.35
0.00
2.50
+0.15
2.65
g
V
0 g Offset over Temperature
mg
from 25C, –40C to +105C
100
based on 1000mV/g
NOISE PERFORMANCE
Noise Density, rms
0.6
1.0
30
Hz
mg/
FREQUENCY RESPONSE
3dB Bandwidth
24
27
Hz
Phase delay
at 5Hz
-18
deg
SELF TEST
Delta Output changes at Xout, Yout
Output voltage under failure
Self Test Pin Pull-Down Resistor (Internal)
Xout and Yout OUTPUTS
Normal Output Range
(Guaranteed symmetric clipping)
Current
-830
5.0
50
mV
V
Kohms
@5.0V Supply
0.5
4.5
100
V
A
mS
Source or sink, @ 4.5V-5.25V supply
@5.0V Supply
Turn-On Time
150
POWER SUPPLY
Operating Voltage Range
Supply Current
4.50
5.00
4.1
5.25
6.0
V
mA
@ 5.0V
TEMPERATURE RANGE
Operating Range
PRESSURE RANGE
Operating Range
-40
40
+105
300
C
KPa.
NOTES
1 Guaranteed by measurement of initial offset and sensitivity.
2 Alignment error is specified as the angle between the true and indicated
axis of sensitivity.
3 Transverse sensitivity is the algebraic sum of the alignment and the
inherent sensitivity errors.
4 The device operates over a 4.5V to 5.25V supply range. The output zero
g reference voltage scales 50% of the supply voltage. Sensitivity has a
linear scale over the supply range of 4.5 to 5.25 volts according to the ratio
(Vdd/5.0 volts) x (1000mV/g).
recommended to filter with a minimum of 200Hz low pass filter.
5
Note that the accelerometer has a constant heater power control circuit
thereby requiring higher supply current at lower operating voltage.
MEMSIC MXR7999V Rev.A
Page 2 of 6
4/14/2009