MX13-SERIES
3 Phase Noise filter for FA Servo System
Ⅵ Features
(1) Suitable for mounting in the control panel:
Height and depth meets the industry standard.
(2) Easy installation and easy maintenance:
Centralized terminals in front surface.
(3) Applicable to NC Servo noise and AC Servo noise:
High attenuation by 40dB at 150kHz. level.
(4) Enriched lineups: 3 types (30A, 50A, 100, 150A)
selectable.
(5) Patent and design registration pending.
Ⅵ Safety standard
UL1283 applied / approval in process
CSA C22.2 No.8 applied / approval in process
EN133200 EN133200 applied / approval in process
*Completion projected in August,2001
Ⅵ Specifications
Model
MX13030
30A
MX13050
50A
MX13100
100A
MX13150
150A
Item
1
Rated voltage
3 Phase AC250V
2
Rated current
3
Test voltage
Terminal - Case: AC2500V, 1min.
4
Isolation resistance
Leak current
Terminal - Case: DC500V, 100Mohm
5
AC250,60Hz : 3.5mA max.
150kHz : 40dB
–25 ~ +85°(derating required depending on the atmosphere temperature)
Conforms to UL1283, CSA_C22.2No.8, EN133200 (to be applied for)
8mA max.
6
Attenuation
7
Operating ambient temperature
Safety standards
Dimensions (W x H x D)
8
9
100A type projected as a new lineup
●
Ⅵ Derating
NOTE
*1 Value for Ta
_> 50
ºC
_>
For Ta 50ºC,derate according to the derating curve
shown on the right
152