MSAU100 SERIES
DC/DC CONVERTER 1W, SMD-Package
Output Specifications
Parameter
Conditions
Min.
---
Typ.
±1.0
±1.2
Max.
±3.0
±1.5
Unit
%
Output Voltage Accuracy
Line Regulation
For Vin Change of 1%
Io=20% to 100%
---
%
Load Regulation
See Model Selection Guide
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Temperature Coefficient
Short Circuit Protection
---
---
---
---
60
---
120
150
mV P-P
mV P-P
mV rms
%/℃
Over Line, Load & Temp.
---
15
±0.01
±0.02
0.5 Second Max.
General Specifications
Parameter
Conditions
60 Seconds
500 VDC
Min.
1000
1000
---
Typ.
---
Max.
---
Unit
VDC
MΩ
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
---
---
100KHz, 1V
40
100
140
---
pF
50
100
---
KHz
Hours
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
2,000,000
Moisture Sensitivity Level (MSL)
IPC/JEDEC J-STD-020D
Level 3
Input Fuse
5V Input Models
12V Input Models
24V Input Models
100mA Slow-Blow Type
500mA Slow-Blow Type
200mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Conditions
Ambient
Min.
-40
---
Max.
Unit
+85
+90
+125
95
℃
℃
℃
Storage Temperature Range
Humidity (non condensing)
-50
---
% rel. H
Cooling
Free-Air convection
Lead Temperature (1.5mm from case for 10Sec.)
---
260
℃
Power Derating Curve
100
100
80
Natural
convection
Natural
convection
80
100LFM
100LFM
200LFM
400LFM
200LFM
60
60
40
400LFM
40
20
20
0
0
~
~
-40
0
20
40
60
80
100 110
-40
0
20
40
60
80
100 110
Ambient Temperature
]
Ambient Temperature
]
(5V & 12Vin)
(24Vin)
Notes
1
2
3
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Ripple & Noise measurement bandwidth is 0-20MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules;
however they may not meet all specifications listed.
4
5
6
All DC/DC converters should be externally fused at the front end for protection.
Other input and output voltage may be available, please contact factory.
Specifications subject to change without notice.
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2011/08/11 REV:5
Page 2 of 4