MP1477 – SYNCHRONOUS, STEP-DOWN CONVERTER WITH INTERNAL MOSFETS
ELECTRICAL CHARACTERISTICS
VIN = 12V, TJ = -40°C to +125°C (7), typical value is tested at TJ = +25°C, unless otherwise noted.
Parameter
Symbol Condition
Min
Typ
Max
10
Units
μA
Supply current (shutdown)
Supply current (quiescent)
HS switch on resistance
LS switch on resistance
Switch leakage
IIN
IQ
VEN = 0V
VEN = 2V, VFB = 0.85V
170
200
58
240
μA
HSRDS(ON) VBST-SW = 3.3V
LSRDS(ON)
mΩ
mΩ
μA
27
SWLKG
ILIMIT
VEN = 0V, VSW = 12V
10
Valley current limit
VOUT = 0V
2.7
-250
600
4
5.8
A
VOUT = 3.3V, Lo = 2.2μH,
IOUT = 0A
ZCD
IZCD
20
250
mA
Oscillator frequency
Minimum on time (8)
Minimum off time (8)
fSW
VFB = 0.75V
800
45
1000
kHz
ns
TON_MIN
TOFF_MIN
180
805
805
10
ns
TJ = +25°C
793
789
817
821
100
mV
mV
nA
VREF
%
Feedback voltage
VREF
TJ = -40°C to 125°C
Feedback current
FB UV threshold (H to L)
Hiccup duty cycle (8)
EN rising threshold
EN hysteresis
IFB
VUV_th
Hiccup entry
VEN = 2V
75%
25
DHiccup
VEN_RISING
VEN_HYS
IEN
1.14
1.2
100
2
1.26
V
mV
µA
EN input current
VIN under-voltage lockout
threshold rising
INUVVth
3.7
1.6
4
4.18
3
V
VIN under-voltage lockout
threshold hysteresis
INUVHYS
330
mV
Soft-start period
Thermal shutdown (8)
Thermal hysteresis (8)
NOTES:
TSS
TSD
2.5
150
20
ms
°C
°C
TSDHYS
7) Guaranteed by over-temperature correlation, not tested in production.
8) Guaranteed by design and engineering sample characterization.
MP1477 Rev. 1.0
9/12/2017
www.MonolithicPower.com
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2017 MPS. All Rights Reserved.
4