Scotchlok™ Terminals
W´
W´
MNU18-187DMI, MNU14-187DMI
Male Disconnect, Nylon Fully Insulated,
Butted Seam
W´
W
D
L
Data Sheet
Wire
Range
(AWG)
Male Tab
Width (W´ )
x Thickness
Maximum
Insulation
Diameter
Product
Number
Barrel
Length
Barrel
I.D.
L
W
D
MNU18-187DMI
MNU14-187DMI
22-18
16-14
0.187 x 0.020
0.187 x 0.020
0.87 0.37 0.30
0.87 0.37 0.30
0.24
0.24
0.080
0.080
0.145
0.145
Installation Information
ꢀWARNING
UNDERWRITERS
CANADIAN STANDARDS
ASSOCIATION
Turn power off before installing or removing terminal. All electrical
work should be done according to appropriate electrical codes.
LABORATORIES
STANDARD NO. UL 310
3M FILE NO. E70512
STANDARD NO. C22.2
NO. 153
UL Listed and CSA Certified for use on stranded copper
(AWG) wire only.
3M FILE NO. LR22190
Strip away the end 3/8 inch of wire insulation.
Make the crimp in the proper station of a recommended
3M crimp tool: TH-440, TH-450 (scissor style), or
TR-490 (ratchet style) hand tool.
Specifications
Wire Size:
Barrel Seam:
Maximum Voltage Rating:
See Table Above
Butted
600 V Building Wire
1000 V Signs or
Fixtures (Luminaires)
Barrel Crimp (Required)
Maximum Temperature Rating: 221˚F (105˚C)
Maximum Current:
Insulator Material:
Terminal Material:
Plating:
Same as Wire
Nylon
ETP Copper
Tin
Suitable for factory application on steel or brass tabs
UL or CSA.
Suitable for field application on brass tabs, strain relief
required, UL only.