TECHNICAL DATA SHEET
6 Lake Street, Lawrence, MA 01841
1-800-446-1158 / (978) 620-2600 / Fax: (978) 689-0803
Website: http: //www.microsemi.com
SINGLE and QUAD 3 Amp & 4 Amp POL REGULATORS
Table 3 – MODEL NUMBER FUNCTIONALITY CHART
PACKAGE TYPE
OUTPUT TYPE
OTHER FUNCTIONALLTY
Output
FORMER P/N
Remote
Internal
Compen-
sation
MODEL NUMBER
NOTES
MO-078 SIP
Flat
Adj Fixed
Note C
Enable Parallelable
Pin
Package
Body
Sense
Volt
Pack
Note A
Note C
Range
MHP8565A$&
3 Amp Series
9
9
9
9
9
1.21–4V
9
9
SAT8565A-3$T-ADJ
SAT8565P-3$T-ADJ
9
MHP8565P$&
3 Amp Series
NO
1.21–4V Ground
MHP8564A$&
MHP8564F$&
MHP8564R$&
MHP8564S$&
4 Amp Series
4 Amp Series
4 Amp Series
4 Amp Series
9
9
9
9
9
9
9
9
9
Note D
Note D
Note D
9
1.21–4V
1.21–4V
1.21–4V
1.21–4V
9
9
SAT8564A-4$F-ADJ
SAT8564F-4$F-x.y
SAT8564R-4$F-x.y
SAT8564S-4$F-ADJ
9
9
9
9
9
NO
MHP8566A$&
Quad 4 Amp
9
9
9
0–4V
9
SAT8566A-15$F-ADJ
Replace “$” with letter to denote required screening level
NOTE A: Parallelable devices have a synchronizing pin so
that units can be driven out of phase from each other for the
purpose of input and output Voltage Bus ripple reduction.
Other functions necessary for Paralleling are also available
C = COTS
H = CLASS H
K = CLASS K
Replace “&” with lead lend option
= No lead bend
NOTE C: Fixed and remote sense part numbers must be
appendaged with fixed value of output Voltage. Example:
MHPSS00504FR$&-1.8 for a 1.8V fixed output.
-1 = SMT lead bend
-2 = lead bend down
-3 = lead bend up
NOTE D: Sync PIN is available. Other functions necessary
for Paralleling are not available.
Products in shaded areas of the main chart are under development
T4-LDS-0117 Rev. 7 (101311)
Page 4 of 17