3
MBC150 Series
PARAMETER
Output Voltage
Output Power4
Fan Output5
DESCRIPTION / CONDITION
SPECIFICATION
5 V to 48 V
150 W
Refer to Model Selection table
Peak Power: 170 W for 2 s
@ 5 A
12 V
120 VAC:
230 VAC:
120 VAC:
230 VAC:
120 VAC:
230 VAC:
84% typical
86% typical
6 ms
10 ms
0.99
Efficiency
Hold Up Time
Power Factor
0.95
Line Regulation
Load Regulation
± 0.5%
± 2.0%
< 10%,
Transient Response
50 to 100% load change, 50 Hz, 50% duty cycle, 0.1A / µs
All outputs
recovery time < 5 ms
Ripple6
1.0 % max
Rise Time
< 100 ms
Set Point Accuracy
Output Voltage Adjustment
Over Current Protection
Over Voltage Protection
Short Circuit Protection
Main output
V1
± 1%
± 3 %
110% typical above rating
110 to 150%
V1
Short term, Automatic recovery
Convection
80 W (5 V model), 100 W (other models)
100 W (5 V model), 150 W (other models)
Cooling
300 LFM
4
Derate output power linearly to 80% from90 VAC to 80 VAC input.
Fan output voltage tolerance is +/-20 %. Peak current for fan output is 1 A.
Ripple is 2 % up to 20 % load and < 1 % above20 % load. Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic
capacitor) in parallel with a 0.1 µF capacitor at rated linevoltage and load ranges.
5
6
Conducted Emissions
Radiated Emissions
EN 55011-B, CISPR22-B, FCC PART15-B
EN 55011 B
Pass
Pass
Input Current Harmonics
Voltage Fluctuation and Flicker
ESD Immunity
EN 61000-3-2
Class D
EN 61000-3-3
Pass
EN 61000-4-2
Level 4, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 4, Criterion A
Criterion A & B
Radiated Field Immunity
Electrical Fast Transient Immunity
Surge Immunity
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
Conducted Immunity
EN 61000-4-6
Magnetic Field Immunity
Voltage Dips, Interruptions
EN 61000-4-8
EN 61000-4-11
North America
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
+1 408 785 5200
© 2021 Bel Power Solutions & Protection