MB5000RUSeries
Compact, 1 x 2 Inch
50W, 4:1 Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min.
Typ.
Max.
9.0
18.0
Units
Key Features:
• 50W Output Power
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
Input Start Voltage
VDC
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• Very High Efficiency
• Compact 1 x 2 Inch Case
• Ten Standard Models
• Remote ON/OFF Control
• Industry Standard Pin-Out
7.5
16.0
Input Shutdown Voltage
VDC
mS
Start-Up Time, See Note 1
Input Filter
Nominal VIN, Constant Resistive Load
30
LC Filter
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 2
Conditions
Min.
Typ.
Max.
1.0
0.5
Units
%
%
VIN = Min to Max
0.5
%
3.3 & 5.0 VOUT Models
12, 15 & 24 VOUT Models
100
150
250
3.0
Ripple & Noise, See Note 3
mV P - P
Transient Recovery Time, See Note 4
Transient Response Deviation
Temperature Coefficient
Output Power Protection
Over Temperature Protection
Output Short Circuit, See Note 5
General
µSec
%
%/°C
%
25% Load Step Change
5.0
0.02
Hiccup Mode
Shutdown Temperature
150
+110
°C
Continuous (Autorecovery)
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
Units
VDC
M⍀
pF
2,200
285
Typ.
+25
kHz
Parameter
Conditions
Min.
Max.
+61
+53
+46
+69
+62
+57
+105
+125
Units
3.3 VOUT Models
Operating Temperature Range,
Ambient Without Heatsink
12, & 15 VOUT Models -40
5.0 & 24 VOUT Models
3.3 VOUT Models
12, & 15 VOUT Models -40
5.0 & 24 VOUT Models
Case
°C
Operating Temperature Range,
Ambient With Heatsink
+25
°C
Operating Temperature Range
Storage Temperature Range
Cooling
°C
°C
-50
Free Air Convection
RH, Non-condensing
Humidity
95
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Physical
Case Size
Case Material
Weight
2.0 x 1.0 x 0.43 Inches (50.8 x 25.4 x 11.0 mm)
Metal with Non-Conductive Base
1.20 Oz (34g)
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Conditions
MIL HDBK 217F, 25°C, Gnd Benign 233.5
Min.
Typ.
Typ.
Max.
Units
kHours
Conditions
Min.
24 VDC Input -0.7
48 VDC Input -0.7
Max.
50.0
100.0
260.0
Units
VDC
°C
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com